Balancing sterilization and functional properties in Poloxamer 407 hydrogels: comparing heat and radiation techniques
Open Access
- 6 January 2025
- journal article
- Published by Oxford University Press (OUP) in Regenerative Biomaterials
- Vol. 12, rbaf005
Abstract
Poloxamer 407, also known as Pluronic® F127, is gaining interest in the cosmetic, biomedical and pharmaceutical fields for its biocompatibility, safety and thermo-sensitive properties. Ensuring sterility is critical in clinical applications, and sterilization is often preferred over aseptic processing. However, sterilization can impact the functional properties of the hydrogel. In this study, we investigate the effects of steam heat (121°C, 20 min), dry heat (160°C, 1 h), gamma irradiation (25 kGy) and electron beam (e-beam) irradiation (15 and 25 kGy) on a 30% w/v Poloxamer 407 hydrogel formulation. Our analysis encompasses gelling properties, pH, Fourier-transform infrared spectroscopy, gel permeation chromatography, small-angle X-ray scattering, rheology, swelling, degradation by-products and lactate dehydrogenase release of the sterilized hydrogels, comparing them to a non-sterile counterpart. We demonstrated that heat sterilization alters the hydrogel’s gelling and structural properties due to water evaporation and oxidation under harsh temperature conditions, especially when applying the dry heat method. Gamma irradiation proved unsuitable, resulting in an acidic and cytotoxic hydrogel due to oxidative degradation. In contrast, e-beam irradiation preserves the hydrogel’s elasticity, gelling and structural properties while enhancing mechanical resilience and moderating swelling. Therefore, e-beam irradiation within the 15–25 kGy range appears to be the most suitable method for sterilizing a 30% w/v Poloxamer 407 hydrogel.Keywords
Funding Information
- Research Council of Norway (331752, 332148, 346292)
This publication has 77 references indexed in Scilit:
- Rheological characterization and in vivo evaluation of thermosensitive poloxamer-based hydrogel for intramuscular injection of piroxicamInternational Journal of Pharmaceutics, 2010
- Effect of sterilisation by gamma irradiation on the ability of polycaprolactone (PCL) to act as a scaffold materialMedical Engineering & Physics, 2008
- In situ gelling stimuli-sensitive block copolymer hydrogels for drug deliveryJournal of Controlled Release, 2008
- Safety Assessment of Poloxamers 101, 105, 108, 122, 123, 124, 181, 182, 183, 184, 185, 188, 212, 215, 217, 231, 234, 235, 237, 238, 282, 284, 288, 331, 333, 334, 335, 338, 401, 402, 403, and 407, Poloxamer 105 Benzoate, and Poloxamer 182 Dibenzoate as Used in CosmeticsInternational Journal of Toxicology, 2008
- Poly(ethylene oxide)–poly(propylene oxide) block copolymer micelles as drug delivery agents: Improved hydrosolubility, stability and bioavailability of drugsEuropean Journal of Pharmaceutics and Biopharmaceutics, 2007
- Sustained Ocular Drug Delivery from a Temperature and pH Triggered Novel In Situ Gel SystemDrug Delivery, 2007
- A Review of Poloxamer 407 Pharmaceutical and Pharmacological CharacteristicsPharmaceutical Research, 2006
- In situ-forming hydrogels—review of temperature-sensitive systemsEuropean Journal of Pharmaceutics and Biopharmaceutics, 2004
- A Study of the Temperature-Dependent Micellization of Pluronic F127Journal of Colloid and Interface Science, 1999
- Gamma Irradiation Effects on Molecular Weight and in Vitro Degradation of Poly(D,L-Lactide-CO-Glycolide) MicroparticlesPharmaceutical Research, 1995