Abstract
Objective: This study applied ISO 50001:2018 EMS guidelines to assess energy consumption and evaluate O&M practices’ impact on the energy efficiency of a Colombian crude oil pipeline. Methodology: A dataset comprising over 80 variables spanning a year (base period) was analyzed to define the significant energy use (SEU) of pipeline operations. An Energy Baseline (EnB) was modeled using linear regression with Non-Controllable Variables (NCVs), excluding Controllable Variables (CVs). An Energy Goal Line (EnG) model was developed through regression of average energy consumption below the EnB. O&M practices, including prioritizing efficient pumps and increasing frequency of pigging, were evaluated over an eight-month monitoring period. An Energy Performance Indicator (EnPI) quantified energy savings. Results: SEU energy consumption was influenced 80% by CVs and 20% by NCVs. The EnB and EnG models exhibited a second-order polynomial relationship involving a linear combination of the NCVs (normalized flow). At the average normalized flow, potential energy savings of 3.7% were identified, attributed to NCV fluctuations and O&M variability during the base period. During the monitoring period, the EnPI indicated energy savings of 1,003.6 MWh, representing a 27% reduction in the base period’s average consumption. Annual extrapolation of O&M estimated energy savings of 1,560.39 MWh, equivalent to 259.02 tCO2-eq and $153,529.37 USD.Conclusion: integrating energy performance monitoring with O&M practices deliver substantial energy, economic, and environmental benefits, providing a robust foundation for continuous improvement in crude oil transportation processes.