Accurate and Standardized Coronary Wave Intensity Analysis
Open Access
- 3 August 2016
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 64 (5) , 1187-1196
Abstract
Objective: Coronary wave intensity analysis (cWIA) has increasingly been applied in the clinical research setting to distinguish between the proximal and distal mechanical influences on coronary blood flow. Recently, a cWIA-derived clinical index demonstrated prognostic value in predicting functional recovery postmyocardial infarction. Nevertheless, the known operator dependence of the cWIA metrics currently hampers its routine application in clinical practice. Specifically, it was recently demonstrated that the cWIA metrics are highly dependent on the chosen Savitzky-Golay filter parameters used to smooth the acquired traces. Therefore, a novel method to make cWIA standardized and automatic was proposed and evaluated in vivo. Methods: The novel approach combines an adaptive Savitzky-Golay filter with high-order central finite differencing after ensemble-averaging the acquired waveforms. Its accuracy was assessed using in vivo human data. The proposed approach was then modified to automatically perform beat wise cWIA. Finally, the feasibility (accuracy and robustness) of the method was evaluated. Results: The automatic cWIA algorithm provided satisfactory accuracy under a wide range of noise scenarios (≤10% and ≤20% error in the estimation of wave areas and peaks, respectively). These results were confirmed when beat-by-beat cWIA was performed. Conclusion: An accurate, standardized, and automated cWIA was developed. Moreover, the feasibility of beat wise cWIA was demonstrated for the first time. Significance: The proposed algorithm provides practitioners with a standardized technique that could broaden the application of cWIA in the clinical practice as enabling multicenter trials. Furthermore, the demonstrated potential of beatwise cWIA opens the possibility investigating the coronary physiology in real time.Keywords
Funding Information
- Department of Health
- National Institute for Health Research Comprehensive Biomedical Research Centre Award
- NHS Foundation Trust
- King's College London and King's College Hospital NHS Foundation Trust
- Centre of Excellence in Medical Engineering
- Wellcome Trust and Engineering and Physical Sciences Research Council (WT 088641/Z/09/Z)
- British Heart Foundation Centre of Research Excellence (BHF RE/08/003)
- British Heart Foundation Clinical Research Training Fellowship (FS/14/11/30526)
This publication has 25 references indexed in Scilit:
- Multiscale Modelling of Cardiac Perfusion2015
- Automatic selection of optimal Savitzky-Golay filter parameters for Coronary Wave Intensity Analysis2014
- Wave speed in human coronary arteries is not influenced by microvascular vasodilation: implications for wave intensity analysisBasic Research in Cardiology, 2014
- Enhancing coronary Wave Intensity Analysis robustness by high order central finite differencesArtery Research, 2014
- Coronary Wave EnergyCirculation: Cardiovascular Interventions, 2013
- Coronary wave intensity during the Valsalva manoeuvre in humans reflects altered intramural vessel compression responsible for extravascular resistanceThe Journal of Physiology, 2012
- Potential and limitations of wave intensity analysis in coronary arteriesMedical & Biological Engineering & Computing, 2009
- Physiological Assessment of Coronary Artery Disease in the Cardiac Catheterization LaboratoryCirculation, 2006
- Single-Wire Pressure and Flow Velocity Measurement to Quantify Coronary Stenosis Hemodynamics and Effects of Percutaneous InterventionsCirculation, 2004
- Smoothing and Differentiation of Data by Simplified Least Squares Procedures.Analytical Chemistry, 1964