Abstract
This paper proposes a novel fault-tolerant control strategy of the open winding inverter for DC-biased vernier reluctance machines (DC-biased-VRMs), aiming to maintain the output capability after the open-circuit fault occurs in the inverter switches. DC-biased-VRMs are with integrated winding current for both DC component for field excitation and AC component for torque generation. The torque generation is not associate with the current direction, making the full-bridge inverter can be divided into two groups of devices. The proposed fault-tolerant control strategy is based on the regular full-bridge inverter for each open-winding, and can control the motor in the fault tolerant mode with one group of devices. When device open circuit fault appears in the normal mode, the controller will switch to the fault tolerant mode. After a short transient period, the motor will be able to work. Moreover, in the fault tolerant mode, a PMW driving method is proposed to reduce the current ripple. The proposed method does not require any additional components, and the reliability of the drive control system is improved considerably. Experimental results verify the validity and feasibility of the proposed fault-tolerant control strategy.
Funding Information
  • National Natural Science Foundation of China (51607078, 51607079, 51520105010)
  • National Key Research and Development Program of China (2017YFB0102300, 2017YFB0102400)
  • Fundamental Research Funds for the Central Universities (2018KFYYXJJ070)

This publication has 25 references indexed in Scilit: