Respiratory signal derived from the smartphone built-in accelerometer during a Respiratory Load Protocol
- 1 August 2015
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2015 (1094687X) , 6768-6771
Abstract
The scope of our work focuses on investigating the potential use of the built-in accelerometer of the smartphones for the recording of the respiratory activity and deriving the respiratory rate. Five healthy subjects performed an inspiratory load protocol. The excursion of the right chest was recorded using the built-in triaxial accelerometer of a smartphone along the x, y and z axes and with an external uniaxial accelerometer. Simultaneously, the respiratory airflow and the inspiratory mouth pressure were recorded, as reference respiratory signals. The chest acceleration signal recorded in the z axis with the smartphone was denoised using a scheme based on the ensemble empirical mode decomposition, a noise data assisted method which decomposes nonstationary and nonlinear signals into intrinsic mode functions. To distinguish noisy oscillatory modes from the relevant modes we use the detrended fluctuation analysis. We reported a very strong correlation between the acceleration of the z axis of the smartphone and the reference accelerometer across the inspiratory load protocol (from 0.80 to 0.97). Furthermore, the evaluation of the respiratory rate showed a very strong correlation (0.98). A good agreement was observed between the respiratory rate estimated with the chest acceleration signal from the z axis of the smartphone and with the respiratory airflow signal: Bland-Altman limits of agreement between -1.44 and 1.46 breaths per minute with a mean bias of -0.01 breaths per minute. This preliminary study provides a valuable insight into the use of the smartphone and its built-in accelerometer for respiratory monitoring.Keywords
This publication has 10 references indexed in Scilit:
- Detrended fluctuation thresholding for empirical mode decomposition based denoisingDigital Signal Processing, 2014
- Respiratory rate detection by empirical mode decomposition method applied to diaphragm mechanomyographic signals2014
- mHealth Technologies for Chronic Diseases and Elders: A Systematic ReviewIEEE Journal on Selected Areas in Communications, 2013
- Ambulatory respiratory rate detection using ECG and a triaxial accelerometer2013
- Evaluation of respiration quality using smart phone2013
- Respiration rate monitoring methods: A reviewPediatric Pulmonology, 2011
- ENSEMBLE EMPIRICAL MODE DECOMPOSITION: A NOISE-ASSISTED DATA ANALYSIS METHODAdvances in Adaptive Data Analysis, 2009
- Respiratory rate: the neglected vital signMedical Journal of Australia, 2008
- The empirical mode decomposition and the Hilbert spectrum for nonlinear and non-stationary time series analysisProceedings of the Royal Society A: Mathematical, Physical and Engineering Sciences, 1998
- Mosaic organization of DNA nucleotidesPhysical Review E, 1994