Clinical performance in continuous curvilinear capsulorhexis creation supported by a digital image guidance system
- 1 March 2017
- journal article
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 43 (3) , 348-352
Abstract
To test whether a default capsulorhexis diameter could be attained more precisely when manual continuous curvilinear capsulorhexis (CCC) creation was supported by a biomorphological detection unit. Ruhr University Eye Hospital, Bochum, Germany. Prospective interventional study. Patients were assigned to either of 2 groups. In the first group, a digital image system was applied to guide capsulorhexis. In the second group, the CCC was created without digital support. Postoperatively, horizontal and vertical capsulorhexis dimensions were measured. A set target diameter of 5.5 mm was compared with intraoperative and postoperative CCC diameters, which were also compared with each other. The number of eyes with postoperative CCC diameters outside the reference range of 4.5 to 6.0 mm was assessed. In 427 eyes, the capsulorhexis size was assessed. Digital image guidance was applied in 203 eyes. Intraoperatively, horizontal capsulorhexis diameters created with surgical guidance differed significantly less from the target diameter than in the control group (P < .001). Eyes treated with surgical guidance differed significantly less from the target diameter (P < .001). Analogously, vertical capsulorhexis diameters differed significantly less from the target when digital support was used, intraoperatively and postoperatively (P < .001). In 418 eyes, postoperative diameters were significantly larger than intraoperatively in both directions (P < .001). Vertical CCC diameters were more frequently within the reference range intraoperatively and postoperatively with surgical guidance (P = .009). Horizontally, eye tracking showed accordance with the target diameter in 87.6% (controls: 91.7%). Intraoperative image guidance facilitated CCC creation significantly during standard phacoemulsification.Keywords
This publication has 10 references indexed in Scilit:
- Femtosecond laser–assisted cataract surgery—current status and future directionsSurvey of Ophthalmology, 2016
- New device for creating a continuous curvilinear capsulorhexisJournal of Cataract & Refractive Surgery, 2014
- Toric intraocular lenses: Historical overview, patient selection, IOL calculation, surgical techniques, clinical outcomes, and complicationsJournal of Cataract & Refractive Surgery, 2013
- New technology for sizing the continuous curvilinear capsulorhexis: Prospective trialJournal of Cataract & Refractive Surgery, 2008
- Ring-shaped caliper for better anterior capsulorhexis sizing and centrationJournal of Cataract & Refractive Surgery, 2006
- The effect of lens edge design versus anterior capsule overlap on posterior capsule opacificationAmerican Journal of Ophthalmology, 2004
- Capsulotomy diameter markJournal of Cataract & Refractive Surgery, 2003
- The effect of capsulorhexis size on posterior capsular opacification: one-year results of a randomized prospective trialAmerican Journal of Ophthalmology, 1999
- Capsular opening contraction after continuous curvilinear capsulorhexis and intraocular lens implantationJournal of Cataract & Refractive Surgery, 1996
- Capsule contraction syndromeJournal of Cataract & Refractive Surgery, 1993