Novel Application of the Dedicated Radial Ventriculography Pigtail Catheter for Selective Pulmonary Artery Engagement in Percutaneous Thrombectomy for Acute Pulmonary Embolism
- 14 June 2026
- journal article
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 108 (3) , 655-657
Abstract
The dedicated radial ventriculography pigtail catheter was originally engineered to facilitate left ventriculography through the radial arterial approach by incorporating a multi‐angulated design optimized for rapid aortic valve traversal. This report describes a novel, descriptive application of this catheter for selective engagement of the left and right pulmonary arteries during percutaneous thrombectomy in acute pulmonary embolism. The catheter's angulation, shaft support, and torque characteristics enable simplified navigation of the right ventricular outflow tract and pulmonary artery bifurcation. This report outlines the rationale, technical approach, and early procedural observations supporting this technique.Keywords
This publication has 4 references indexed in Scilit:
- Catheter-based techniques for pulmonary embolism treatmentEuroIntervention, 2025
- Percutaneous Management of High-Risk Pulmonary EmbolismCirculation: Cardiovascular Interventions, 2023
- Contemporary National Trends and Outcomes of Pulmonary Embolism in the United StatesThe American Journal of Cardiology, 2022
- Dedicated radial ventriculography pigtail catheterCardiovascular Revascularization Medicine, 2013