Fretting wear behaviour of titanium modified by heat treatment
Authors:
- 1 May 2011
- journal article
- research article
- Published by SAGE Publications in Surface Engineering
- Vol. 27 (4) , 246-252
Abstract
Fretting damage is one of the factors leading to failure of orthopaedic implants. The present work studied the fretting behaviour of heat treated titanium in air and water vapour respectively. The tribological experiments were performed with a fretting tester under dry friction and lubrication conditions with the simulated body fluid (SBF). The worn surfaces of the specimens were analysed by scanning electron microscopy with X-ray energy dispersion spectroscope, confocal laser microscope and X-ray diffractometer. Heat treatments enhanced fretting wear resistance and decreased friction coefficients of titanium under dry friction and SBF lubrication conditions respectively. The effect of heat treatment in water vapour was superior to that in air. SBF as lubricant could decrease the wear and friction coefficients of non-heat treated and heat treated titanium.Keywords
This publication has 21 references indexed in Scilit:
- Fretting wear studies on uncoated, plasma nitrided and laser nitrided biomedical titanium alloysMaterials Science and Engineering: A, 2007
- Effect of surface treatments on fretting fatigue damage of biomedical titanium alloysTribology International, 2007
- Improving Wear Resistance by Heat-Treatment in Different AtmospheresKey Engineering Materials, 2005
- Tribological behaviour of plasma nitrided Ti-5Al-2Nb-1Ta alloy against UHMWPETribology International, 2004
- Surface characterization of titanium and adsorption of bovine serum albuminMaterials Characterization, 2002
- Tribological behaviour of DLC coatings compared to different materials used in hip joint prosthesesWear, 2001
- Fatigue of biomaterials: a reviewInternational Journal of Fatigue, 2000
- Friction and wear properties of carbon-ion implanted titanium nitride filmsSurface and Coatings Technology, 2000
- Effect of oxygen implantation upon the corrosion resistance of the OT-4-0 titanium alloySurface and Coatings Technology, 1997
- Surface characterization of C/Ti-6Al-4V coating treated with ion beamBiomaterials, 1997