Transcranial magnetic stimulation safety from operator exposure perspective
- 13 December 2019
- journal article
- research article
- Published by Springer Nature in Medical & Biological Engineering & Computing
- Vol. 58 (2) , 249-256
Abstract
A simulated model of a commercial transcranial magnetic stimulation (TMS) coil is analyzed to determine electromagnetic field (EMF) exposure for an operator while holding or adjusting the coil. Induced EMF strengths are calculated using a commercial figure-8 coil geometry and pulse configuration, with geometrical representations of the subject’s head and the operator’s head, torso, and hand. Exposure levels are compared to experimental results in the literature and international guidelines for occupational EMF exposure limits. Exposure limit guidelines of 0.8 V/m rms are exceeded at approximately 24.6 cm from the coil for the torso model and at 20.3 cm for the head model measured perpendicular to the plane of the coil. In the plane of the coil, the operator can approach closer without exceeding guidelines. The results in the hand model along the edge of the coil give 9.9 V/m and 88.5 V/m for average and peak field strength, respectively. A discussion of the potential consequences of operator exposure to fields exceeding published guidelines concludes that since the guidelines are only concerned with acute effects and do not suggest any potential chronic effects, occupational exposure in the context of delivering TMS treatment may be considered reasonable.Keywords
Funding Information
- Natural Sciences and Engineering Research Council of Canada
- CMC Microsystems
This publication has 14 references indexed in Scilit:
- The European Union physical agents (electromagnetic fields) directive: an update for the MRI communityBritish Journal of Radiology, 2013
- Optically tracked neuronavigation increases the stability of hand-held focal coil positioning: Evidence from “transcranial” magnetic stimulation-induced electrical field measurementsBrain Stimulation, 2010
- Safety, ethical considerations, and application guidelines for the use of transcranial magnetic stimulation in clinical practice and researchClinical Neurophysiology, 2009
- Improved EEG source analysis using low‐resolution conductivity estimation in a four‐compartment finite element head modelHuman Brain Mapping, 2008
- Measurements of occupational exposure to switched gradient and spatially‐varying magnetic fields in areas adjacent to 1.5T clinical MRI systemsJournal of Magnetic Resonance Imaging, 2007
- Investigation of the critical geometric characteristics of living human skulls utilising medical image analysis techniquesInternational Journal of Vehicle Safety, 2007
- Therapeutic staff exposure to magnetic field pulses during TMS/rTMS treatmentsBioelectromagnetics, 2005
- Peripheral Nerve Stimulation by Gradient Switching Fields in Magnetic Resonance ImagingIEEE Transactions on Biomedical Engineering, 2004
- GUIDANCE ON DETERMINING COMPLIANCE OF EXPOSURE TO PULSED AND COMPLEX NON-SINUSOIDAL WAVEFORMS BELOW 100 KHZ WITH ICNIRP GUIDELINESHealth Physics, 2003
- Magnetic stimulation coil and circuit designIEEE Transactions on Biomedical Engineering, 2000