Data electronically extracted from the electronic health record require validation

Authors:

Abstract
Determine sources of error in electronically extracted data from electronic health records. Categorical and continuous variables related to early-onset neonatal hypoglycemia were preselected and electronically extracted from records of 100 randomly selected neonates within 3479 births with laboratory-proven early-onset hypoglycemia. Extraction language was written by an information technologist and data validated by blinded manual chart review. Kappa coefficient assessed categorical variables and percent validity continuous variables. 8/23 (35%) categorical variables had acceptable Κappa (1–0.81); 5/23 (22%) had fair-slight agreement, Κappa < 0.40. Notably, “hypoglycemia” had poor agreement, Κappa 0.16. In contrast, 6/8 continuous variables had validity ≥ 94%. After correcting extraction language, 6/9 variables were corrected and inter-rater validation improved. However, “hypoglycemia” was not corrected, remaining an issue. Data extraction without validation procedures, especially categorical variables using International Classification of Diseases-9 (ICD-9) codes, often results in incorrect data identification. Electronically extracted data must incorporate built-in validating processes.
Funding Information
  • George L. MacGregor Professorship in Pediatrics

This publication has 14 references indexed in Scilit: