Morphologic features and surgically induced astigmatism of femtosecond laser versus manual clear corneal incisions
Authors:
- 1 November 2017
- journal article
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 43 (11) , 1430-1435
Abstract
To compare the morphologic features and surgically induced astigmatism (SIA) between laser and manual clear corneal incisions (CCIs) after femtosecond laser-assisted cataract surgery. Eye Center, 2nd Affiliated Hospital, Medical College of Zhejiang University, Hangzhou, China. Prospective case series. Patients had femtosecond laser-assisted cataract surgery with a CCI created with the laser or manually after random allocation. The corrected distance visual acuity, corneal topography, and anterior segment optical coherence tomography were assessed at the 1-day, 1-week, 1-month, and 3-month follow-ups. The laser CCI group comprised 45 eyes and the manual CCI group, 48 eyes. The SIA was significantly lower in the manual CCI group than the laser CCI group at all visits (P < .05). At the 1-day and 1-week follow-ups, the mean CCI thickness was significantly smaller in the manual CCI group (P < .05). In the laser CCI group, the perpendicular linear distance between the external wound opening and the corneal vertex central line was statistically shorter than in the manual CCI group (P < .05). At 3 months, the SIA was correlated with the perpendicular linear distance with a Pearson correlation coefficient of -0.341 (P = .001). Femtosecond laser-created CCIs for cataract surgery caused more SIA than manually created CCIs, which could have resulted from inaccurate or uncertain corneal incision positioning of the femtosecond machine. Manual creation of CCIs is recommended in femtosecond laser-assisted cataract surgery until the locating system for the femtosecond laser incision is updated.Keywords
Funding Information
- Zhejiang Key Laboratory Fund of China (2011E10006)
This publication has 16 references indexed in Scilit:
- Clinical outcomes of femtosecond laser–assisted cataract surgery versus conventional phacoemulsification surgery for hard nuclear cataractsJournal of Cataract & Refractive Surgery, 2017
- Evaluation of dry eye after femtosecond laser–assisted cataract surgeryJournal of Cataract & Refractive Surgery, 2015
- Optical coherence tomography and 3-dimensional confocal structured imaging system–guided femtosecond laser capsulotomy versus manual continuous curvilinear capsulorhexisJournal of Cataract & Refractive Surgery, 2014
- Efficacy of anterior capsulotomy creation in femtosecond laser–assisted cataract surgeryJournal of Cataract & Refractive Surgery, 2014
- Corneal endothelial cell loss and corneal thickness in conventional compared with femtosecond laser–assisted cataract surgery: Three-month follow-upJournal of Cataract & Refractive Surgery, 2013
- Effectiveness and safety of femtosecond laser–assisted lens fragmentation and anterior capsulotomy versus the manual technique in cataract surgeryJournal of Cataract & Refractive Surgery, 2013
- Comparison of IOL Power Calculation and Refractive Outcome After Laser Refractive Cataract Surgery With a Femtosecond Laser Versus Conventional PhacoemulsificationJournal of Refractive Surgery, 2012
- Internal Aberrations and Optical Quality After Femtosecond Laser Anterior Capsulotomy in Cataract SurgeryJournal of Refractive Surgery, 2011
- Initial Clinical Evaluation of an Intraocular Femtosecond Laser in Cataract SurgeryJournal of Refractive Surgery, 2009
- Corneal shape changes after temporal and superolateral 3.0 mm clear corneal incisionsJournal of Cataract & Refractive Surgery, 1999