Abstract
Traumatic aortic dissection following sudden deceleration injury requires urgent treatment as it may result in formation of aneurysm that may expand or rupture leading to catastrophe. Confirmation of diagnosis of aortic dissection often requires contrast-enhanced computed tomography (CECT) or magnetic resonance imaging, which is time-consuming. Often, there is a significant time lag between the CECT chest and surgical intervention. Progression of aortic dissections may be missed on CECT chest, which would be done in the initial hours after injury. Transesophageal echocardiography (TEE) is equally efficient for the diagnosis of aortic dissection. It may also provide additional information that can be very useful for the management. We report the case of a descending thoracic aortic dissection where TEE plays a crucial role during the surgical management of the patient.Keywords
This publication has 6 references indexed in Scilit:
- Diagnostic Accuracy of Transesophageal Echocardiography, Helical Computed Tomography, and Magnetic Resonance Imaging for Suspected Thoracic Aortic DissectionArchives of internal medicine (1960), 2006
- Traumatic type b aortic dissection causing near total occlusion of aortic lumen and diagnosed by transthoracic echocardiography: a case reportJournal of the American Society of Echocardiography, 2004
- Blunt Trauma Injuries of the Trunk and Extremities2001
- Aortic injury in vehicular traumaThe Annals of Thoracic Surgery, 1994
- Usefulness of transesophageal echocardiography in assessment of aortic dissection.Circulation, 1991