Preparation of Cobalt Oxide Nanoclusters/Overoxidized Polypyrrole Composite Film Modified Electrode and Its Application in Nonenzymatic Glucose Sensing
Authors:
- 10 June 2013
- journal article
- research article
- Published by Wiley in Electroanalysis
- Vol. 25 (7) , 1665-1674
Abstract
A cobalt oxide nanocluster/overoxidized polypyrrole composite film electrochemical sensing interface was fabricated by two step electrochemical method. The electrochemical properties and electrocatalytic activity of the resulting modified electrode were also studied carefully. The results showed that this modified electrode exhibited good stability, good anti‐interference ability, as well as high electrocatalytic activity to the oxidation of glucose. The linear range for the amperometric determination of glucose was 2.0×10−7–2.4×10−4 mol L−1 and 2.4×10−4–1.4×10−3 mol L−1 with a detection limit of 5.0×10−8 mol L−1 (S/N=3), respectively. The sensitivity was 1024 µA mM−1 cm−2.Keywords
This publication has 48 references indexed in Scilit:
- Electrochemical preparation of cobalt hexacyanoferrate nanoparticles under the synergic action of EDTA and overoxidized polypyrrole filmElectrochimica Acta, 2012
- A Novel Process for the Fabrication of a Silver‐Nanoparticle‐Modified Electrode and Its Application in Nonenzymatic Glucose SensingElectroanalysis, 2012
- The nanocomposite of PtPd nanoparticles/onion-like mesoporous carbon vesicle for nonenzymatic amperometric sensing of glucoseSensors and Actuators B: Chemical, 2011
- Electrogenerated Chemiluminescence Detection in Paper-Based Microfluidic SensorsAnalytical Chemistry, 2011
- Nonenzymatic glucose sensor based on flower-shaped Au@Pd core–shell nanoparticles–ionic liquids composite film modified glassy carbon electrodesElectrochimica Acta, 2010
- Electrodeposited MnO2/Au composite film with improved electrocatalytic activity for oxidation of glucose and hydrogen peroxideElectrochimica Acta, 2010
- Emerging synergy between nanotechnology and implantable biosensors: A reviewBiosensors and Bioelectronics, 2010
- Nonenzymatic glucose detection at ordered mesoporous carbon modified electrodeBioelectrochemistry, 2009
- Nanomolar detection of hydrogen peroxide on glassy carbon electrode modified with electrodeposited cobalt oxide nanoparticlesAnalytica Chimica Acta, 2007
- Characterization of Spinel‐Type Cobalt and Nickel Oxide Thin Films by X‐Ray Near Grazing Diffraction, Transmission and Reflectance Spectroscopies, and Cyclic VoltammetryJournal of the Electrochemical Society, 1995