Light wavelength effects in submicrometer phosphor materials using Mie scattering and Monte Carlo simulation
Author:
- 17 September 2013
- journal article
- Published by Wiley in Medical Physics
- Vol. 40 (10) , 101911
Abstract
Purpose:: Phosphor materials provide challenges to both fundamental research and breakthrough development of technologies in research areas. In recent years, with the development of science and technology in the field of materials, a number of physical or chemical synthesis methods have been developed and successfully used for the preparation of submicrometer‐sized phosphors. The present paper provides a rigorous analysis of light diffusion capabilities of phosphor materials in submicrometer‐scale investigating the effect of light wavelength.Methods:: Mie scattering theory and Monte Carlo simulation techniques were used for the optical diffusion performance providing numerical calculations. The Monte Carlo model included: (i) phosphor layers composed of different thickness (200, 500, 1000μm) and (ii) different light wavelength values (420, 545, 610 nm) corresponding to different types of activators, such as Ce, Tb, and Eu activators, respectively.Results:: Based on Mie calculations, it was found that for low values of refractive index (e.g., 1.4) and for particle radius from 250 up to 500 nm no significant variations occurred on optical parameters. Monte Carlo simulations showed that the resolution increases as light wavelength decreases, respectively, however, this increase is more obvious at lower thickness values (i.e., at 200μm). In particular, as light wavelength decreases from 610 down to 545 and 420 nm, the resolution increases 4.4% and 13.9%, respectively (at 200 μm layer thickness). In addition, as layer thickness increases from 200 up to 500 μm the resolution decreases 50.2% while an increase up to 1000 μm causes a decrease of 70.2% (at 420 nm light wavelength).Conclusions:: The goal of the authorˈs study was to investigate the optical diffusion characteristics of submicrometer phosphor materials using Mie scattering theory and Monte Carlo simulation. The present investigation indicated that a key parameter on resolution improvement was the amount of light loss which depends on the choice of activator and affects the lateral spreading.Keywords
This publication has 31 references indexed in Scilit:
- Flat Panel Detectors for Digital Radiography2010
- Image Quality Metrics for Digital Systems2010
- The Monte Carlo evaluation of noise and resolution properties of granular phosphor screensPhysics in Medicine & Biology, 2009
- Anisotropic Light Diffusion: An Oxymoron?Physical Review Letters, 2007
- Homogeneously precipitated Lu2O3:Eu nanocrystalline phosphor for X-ray detectionSensors and Actuators B: Chemical, 2005
- Development of nanophosphors—A reviewMaterials Science and Engineering: R: Reports, 2005
- Synthesis and characterisation of rare earth oxysulphide phosphors. I. Studies on the preparation of Gd2O2S:Tb phosphor by the flux methodOptical Materials, 2004
- X-ray detectors for digital radiographyPhysics in Medicine & Biology, 1997
- The role of screen parameters and print-through in the performance of film/screen systemsPhysics in Medicine & Biology, 1993
- Optical properties of normal and diseased human breast tissues in the visible and near infraredPhysics in Medicine & Biology, 1990