Experimental Investigation of Composite Moment Connections with External Stiffeners
Authors:
- 1 October 2013
- journal article
- Published by SAGE Publications in Advances in Structural Engineering
- Vol. 16 (10) , 1683-1700
Abstract
This paper presents tensile behavior for Concrete-Filled Tubular (CFT) column to H-beam welded connections. These connections were reinforced externally with T-shaped stiffeners at the junction of column and beam. Tensile loading tests and analyses were carried out for the T-stiffener connections. The results demonstrated that the overall behavior and failure modes of all the specimens were governed mainly by the horizontal stiffeners rather than by the vertical stiffeners, while the vertical stiffener only played a role in transferring the load introduced from beam to column. In addition, a simple design method for the T-stiffeneris suggested, with consideration of the effects of the shear strength of the horizontal stiffener and yield line mechanism of the column flange. The prediction and test results are compared and they are in good agreement.Keywords
This publication has 24 references indexed in Scilit:
- Cyclic response characteristics of retrofitted moment resisting connectionsJournal of Constructional Steel Research, 2009
- Axial Load Behavior of Rectangular CFT Stub Columns with Binding BarsAdvances in Structural Engineering, 2007
- Moment Connections to Circular Concrete-Filled Steel Tube ColumnsJournal of Structural Engineering, 2004
- Seismic performance of steel beams to concrete-filled steel tubular column connectionsJournal of Constructional Steel Research, 2003
- CONNECTION BETWEEN HIGH-STRENGTH CONCRETE-FILLED SQUARE TUBULAR STEEL COLUMN AND STEEL BEAM REINFORCED WITH EXTERNAL VERTICAL STIFFENER : Elasto-plastic behavior of the connection and subassemblage frameJournal of Structural and Construction Engineering (Transactions of AIJ), 1999
- Yield line analysis of RHS connections with axial loadsJournal of Constructional Steel Research, 1998
- CONNECTION BETWEEN HIGH-STRENGTH CONCRETE-FILLED SQUARE TUBULAR STEEL COLUMN AND STEEL BEAM, REINFORCED WITH INTERNAL DIAPHRAGM : Local elasto-plastic behavior of the connectionJournal of Structural and Construction Engineering (Transactions of AIJ), 1996
- GENERAL MOMENT-ROTATION CHARACTERISTICS OF BEAM-TO-RHS-COLUMN CONNECTIONS WITHOUT DIAPHRAMSJournal of Structural and Construction Engineering (Transactions of AIJ), 1996
- W-shape beam to RHS column connectionsCanadian Journal of Civil Engineering, 1990
- Predicting the strength of branch plate – RHS connections for punching shearCanadian Journal of Civil Engineering, 1982