An open-walled ionization chamber appropriate to tritium monitoring for glovebox
- 1 July 2010
- journal article
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 81 (7) , 073302
Abstract
An open-walled ionization chamber is developed to monitor the tritium concentration in gloveboxes in tritium processing systems. Two open walls are used to replace the sealed wall in common ionization chambers, through which the tritium gas can diffuse into the chamber without the aid of pumps and pipelines. Some basic properties of the chamber are examined to evaluate its performance. Results turn out that an open-walled chamber of 1 l in volume shows a considerably flat plateau over 700 V for a range of tritium concentration. The chamber also gives a good linear response to gamma fields over 4 decades under a pressure condition of 1 atm. The pressure dependence characteristics show that the ionization current is only sensitive at low pressures. The pressure influence becomes weaker as the pressure increases mainly due to the decrease in the mean free path of β particles produced by tritium decay. The minimum detection limit of the chamber is 3.7×105 Bq/m3.Keywords
This publication has 10 references indexed in Scilit:
- Tritium monitoring in the ITER neutral beam test facilityFusion Engineering and Design, 2007
- Comprehensive review and critical evaluation of the half-life of tritiumJournal of Research of the National Institute of Standards and Technology, 2000
- In-vessel tritium measurements using beta decay in the Tokamak Fusion Test ReactorReview of Scientific Instruments, 1999
- A fast responding tritium in air monitor for use in operational areas of heavy water power reactorsNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1995
- Tritium Sampling and MeasurementHealth Physics, 1993
- A small ionization chamber appropriate to tritium processing systemsFusion Engineering and Design, 1991
- Ionization chamber system to eliminate the memory effect of tritiumNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1989
- Application of air proportional counters to a tritium-in-air monitorNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1987
- A tritium monitoring system using the coherent demodulation techniqueNuclear Instruments and Methods in Physics Research, 1983
- A new method for atmospheric tritium measurement by a source modulation techniqueNuclear Instruments and Methods, 1980