On the Construction and Calibration of Dual‐Probe Heat Capacity Sensors
Authors:
- 1 July 2004
- journal article
- Published by Wiley in Soil Science Society of America Journal
- Vol. 68 (4) , 1185-1190
Abstract
Dual‐probe heat‐capacity (DPHC) sensors can be used to measure soil heat capacity ( C ), water content, and temperature. Research was conducted to test design factors that affect sensor calibration, including: (i) calibration media, (ii) diameter and length of the needle probes, (iii) sensor body material, and (vi) duration and total power of the applied heat pulse. All sensors were calibrated in media with known C , including: agar (water), water‐saturated glass beads, and dry glass beads. Calibration consisted of collecting heat pulse data in a given media and then calculating the apparent probe spacing ( r app , distance between heater and detector needles) that yielded correct value of C An ideal sensor would have the same r app regardless of media type. The r app for all sensor designs increased as C decreased, on average changing by 6.7% between agar and dry beads. This undesirable result was consistent with previous studies that showed DPHC sensors calibrated in agar overestimated C in drier soils. Needle diameter (1.27 vs. 1.65 mm), sensor body material (urethane vs. high‐conductivity epoxy), and shortening of the detector probe had a small effect on r app Sensors made with urethane bodies, 1.27‐mm diam. needle probes, and shortened temperature probes showed less sensitivity to calibration media and are therefore recommended. The r app for this design only increased by 2.6% between dry and water‐saturated wet beads. Apparent probe spacing was not affected by changes in total applied power (400–1600 J m −1 ) or heat pulse duration (2–16 s) when the correct analytical model was used to compute CKeywords
Funding Information
- Cooperative State Research, Education, and Extension Service, USDA (2001-38700-11092)
This publication has 10 references indexed in Scilit:
- SIMPLIFIED COMPUTATIONAL APPROACH FOR DUAL‐PROBE HEAT‐PULSE METHODSoil Science Society of America Journal, 2004
- Use of the Dual‐Probe Heat‐Pulse Technique to Monitor Soil Water Content in the Vadose ZoneVadose Zone Journal, 2003
- Field Evaluation of the Dual‐Probe Heat‐Pulse Method for Measuring Soil Water ContentVadose Zone Journal, 2003
- Laboratory Evaluation of the Dual‐Probe Heat‐Pulse Method for Measuring Soil Water ContentVadose Zone Journal, 2003
- Dual Thermal Probes near Plane InterfacesSoil Science Society of America Journal, 1999
- Measuring Soil Water Content under Turfgrass Using the Dual-probe Heat-pulse TechniqueJournal of the American Society for Horticultural Science, 1998
- Measuring Soil Water Content in the Laboratory and Field with Dual‐Probe Heat‐Capacity SensorsAgronomy Journal, 1997
- Error Analysis of the Heat Pulse Method for Measuring Soil Volumetric Heat CapacitySoil Science Society of America Journal, 1993
- Test of a Heat‐Pulse Probe for Measuring Changes in Soil Water ContentSoil Science Society of America Journal, 1993
- Probe for Measuring Soil Specific Heat Using A Heat‐Pulse MethodSoil Science Society of America Journal, 1991