Mechanical Stimulation of Red Blood Cells Aging: Focusing on the Microfluidics Application
Open Access
- 25 February 2025
- journal article
- review article
- Published by MDPI AG in Micromachines
- Vol. 16 (3) , 259
Abstract
Human red blood cells (RBCs) are highly differentiated cells, essential in almost all physiological processes. During their circulation in the bloodstream, RBCs are exposed to varying levels of shear stress ranging from 0.1–10 Pa under physiological conditions to 50 Pa in arterial stenotic lesions. Moreover, the flow of blood through splenic red pulp and through artificial organs is associated with brief exposure to even higher levels of shear stress, reaching up to hundreds of Pa. As a result of this exposure, some properties of the cytosol, the cytoskeleton, and the cell membrane may be significantly affected. In this review, we aim to systematize the available information on RBC response to shear stress by focusing on reported changes in various red cell properties. We pay special attention to the results obtained using microfluidics, since these devices allow the researcher to accurately simulate blood flow conditions in the capillaries and spleen.Keywords
All Related Versions
This publication has 213 references indexed in Scilit:
- Cyclic Mechanical Stresses Alter Erythrocyte Membrane Composition and Microstructure and Trigger Macrophage PhagocytosisAdvanced Science, 2022
- Erythrocyte flow through the interendothelial slits of the splenic venous sinusBiomechanics and Modeling in Mechanobiology, 2021
- Production of erythrocyte microparticles in a sub-hemolytic environmentJournal of Artificial Organs, 2021
- Stomatin is highly expressed in exosomes of different origin and is a promising candidate as an exosomal markerJournal of Cellular Biochemistry, 2020
- Red blood cell tolerance to shear stress above and below the subhemolytic thresholdBiomechanics and Modeling in Mechanobiology, 2019
- Modeling and prediction of flow-induced hemolysis: a reviewBiomechanics and Modeling in Mechanobiology, 2019
- High Aspect Ratio Sub‐Micrometer Channels Using Wet Etching: Application to the Dynamics of Red Blood Cell Transiting through Biomimetic Splenic SlitsSmall, 2017
- A biomimetic microfluidic chip to study the circulation and mechanical retention of red blood cells in the spleenAmerican Journal of Hematology, 2015
- Evaluation of hemolysis in patients with prosthetic heart valvesClinical Cardiology, 1998
- Red blood cell rouleaux formation in dextran solution: dependence on polymer conformationEuropean Biophysics Journal, 1998