A METHOD TO ESTIMATE THE EARLY AGE COMPRESSIVE STRENGTH OF CONCRETE BEFORE DEMOLDING USING A PIN PENETRATION DEVICE

Authors:

Abstract
This study proposed a method to estimate the compressive strength of early-age concrete before demolding using a pin penetration device. Small holes were prepared on molds to apply for this method. A strong correlation was obtained between pin penetration depth and compressive strength despite the materials and mix proportions difference. This method was applicable between 5 and 15 MPa compressive strength, which is the demolding criterion. Within the experimental results, the penetration depths of 12.5, 9.5, and 8.5 mm (Flat), and 13.0, 10.0, and 9.0 mm (Sharp) were sufficient to demolding criteria of 5, 10, and 15 MPa, respectively.

This publication has 8 references indexed in Scilit: