Early Loading of Machined‐Surf ace Brånemark Implants in Completely Edentulous Mandibles: Healed Bone versus Fresh Extraction Sites
Authors:
- Hugo De BruynHBHugo De Bruyn
- Bruno CollaertBCBruno Collaert
- 30 October 2002
- journal article
- Published by Wiley in Clinical Implant Dentistry and Related Research
- Vol. 4 (3) , 136-142
Abstract
Background: Restoration of edentulous mandibles with dental implants installed with a two‐stage or one‐stage surgical approach, yet with delayed loading, is a predictable and successful treatment. Purpose: The present prospective study evaluated the success up to 3 years of function of nonroughened machined‐surface Brånemark System implants (Nobel Biocare AB, Gothenburg, Sweden) loaded early or immediately with a fixed 12‐unit bridge. Materials and Methods: In total, 184 implants were installed in 36 patients:30 with healed bone and 6 with some remaining teeth, which were extracted simultaneously with implant installation. The provisional or final prostheses were installed 0 to 52 (mean 18.2) days later. Results: Thirteen of 184 (7.1%) implants failed within 3 months of loading in 5 of 36 (13.9%) patients:1 of 153 implants (0.7%) failed in healed bone, and 12 of 31 (39%) failed in fresh extraction sites. This consequently meant a loss of 3 of 36 (8.3%) prostheses, all in the extraction group. No implants were lost during 3 years of functional loading (16 patients, 75 implants). The average marginal bone level measured initially and after 1, 2, and 3 years was 0.8 mm (SD = 0.5), 1.0 mm (SD = 0.4), 1.1 mm (SD = 0.3), and 1.4 mm (SD = 0.5), respectively. Conclusions: Four to six Brånemark implants with nonroughened machined titanium surfaces can be loaded early or immediately with cross‐arch restorations in healed mandibulary bone, but this cannot be recommended for fresh extraction sites.Keywords
This publication has 14 references indexed in Scilit:
- Early Loading of Four or Five Astra Tech Fixtures with a Fixed Cross-Arch Restoration in the MandibleClinical Implant Dentistry and Related Research, 2002
- Infectious risks for oral implants: a review of the literatureClinical Oral Implants Research, 2002
- Early Functional Loading of Brånemark Dental Implants: 5‐Year Clinical Follow‐up StudyClinical Implant Dentistry and Related Research, 2000
- Immediate functional loading of Brånemark dental implants. An l8‐month clinical follow‐up studyClinical Oral Implants Research, 1999
- A Prospective Clinical Trial of Endosseous Screw‐Shaped Implants Placed at the Time of Tooth Extraction Without AugmentationJournal of Periodontology, 1998
- Some clinical and radiographical features of submerged and non‐submerged titanium implants. A 5‐year follow‐up study.Clinical Oral Implants Research, 1997
- Patient's opinion and treatment outcome of fixed rehabilitation on Brinemark implants. A 3‐year follow‐up study in private dental practices.Clinical Oral Implants Research, 1997
- Osseointegration of Brånemark fixtures using a single‐step operating technique. A preliminary prospective one‐year study in the edentulous mandible.Clinical Oral Implants Research, 1995
- The effect of smoking on early implant failureClinical Oral Implants Research, 1994
- Clinical and radiographical features of submerged and nonsubmerged titanium implantsClinical Oral Implants Research, 1994