Low-Dose Spiral CT: Application to Surface-Rendered Three-Dimensional Imaging of Central Airways
Authors:
- Yo Won ChoiYCYo Won Choi
- H. Page McAdamsHMH. Page McAdams
- Seok Chol JeonSJSeok Chol Jeon
- Choong Ki ParkCPChoong Ki Park
- Soo-Jin LeeSLSoo-Jin Lee
- Bong-Soo KimBKBong-Soo Kim
- Jong Hyo KimJKJong Hyo Kim
- Chang Kok HahmCHChang Kok Hahm
- 1 May 2002
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Computer Assisted Tomography
- Vol. 26 (3) , 335-341
Abstract
The purpose of this work was to assess the utility of low-dose spiral CT for three-dimensional imaging of the central airways. Spiral CT was performed in 15 patients using two tube currents (50 and 240 mA), producing 30 CT data sets. Surface-rendered virtual bronchoscopy (VB) and shaded surface display (SSD) images were assessed by three radiologists for image quality. The radiologists were also asked to compare 15 matched pairs each of 50 and 240 mA VB and SSD images, blindly select the 240 mA image, and record differences in diagnostic quality between the matched images. No significant difference in image quality was noted with 50 or 240 mA. Only 51.1% of 240 mA SSD and 51.1% of 240 mA VB images were correctly identified. Differences in diagnostic quality, noted in 84.4% of SSD and 33% of VB image pairs, were not ascribed to image noise. Image quality of surface-rendered three-dimensional images of the central airways is preserved using a lower tube current.Keywords
This publication has 22 references indexed in Scilit:
- Bronchial anastomotic complications in lung transplant recipients: virtual bronchoscopy for noninvasive assessment.Radiology, 1998
- Virtual bronchoscopy for directing transbronchial needle aspiration of hilar and mediastinal lymph nodes: a pilot study.American Journal of Roentgenology, 1998
- CT virtual bronchoscopy of simulated endobronchial lesions: effect of scanning, reconstruction, and display settings and potential pitfalls.American Journal of Roentgenology, 1998
- Evaluation of tracheobronchial disease with helical CT with multiplanar and three-dimensional reconstruction: correlation with bronchoscopy.RadioGraphics, 1997
- Perspective volume rendering of CT and MR images: applications for endoscopic imaging.Radiology, 1996
- Airways and lung: correlation of CT with fiberoptic bronchoscopy.Radiology, 1995
- 3D Spiral CT of the Tracheobronchial TreeJournal of Computer Assisted Tomography, 1995
- Low-dose CT of the lungs: preliminary observations.Radiology, 1990
- Detection of Bronchial AbnormalitiesJournal of Computer Assisted Tomography, 1987
- Comparison of CT and fiberoptic bronchoscopy in the evaluation of bronchial diseaseAmerican Journal of Roentgenology, 1987