Surgical approach to the facial recess influences the acceptable trajectory of cochlear implantation electrodes
Authors:
- 5 February 2021
- journal article
- research article
- Published by Springer Nature in European Archives of Oto-Rhino-Laryngology
- Vol. 279 (1) , 137-147
Abstract
Purpose To provide practical guidance to the operative surgeon by mapping the location, where acceptable straight-line virtual cochlear implant electrode trajectories intersect the facial recess. In addition, to investigate the influence of facial recess preparation, virtual electrode width and surgical approach to the cochlea on these available trajectories. Methods The study was performed on imaging data from eight cadaveric temporal bones within the University of Melbourne Virtual Reality (VR) Temporal Bone Surgery Simulator. The facial recess was opened to varying degrees, and acceptable trajectory vectors with varying diameters were calculated for electrode insertions via cochleostomy or round window membrane (RWM). The percentage of acceptable insertion vectors through each location of the facial recess was visually represented using heatmaps. Results Seven of the eight bones allowed for acceptable vector trajectories via both cochleostomy and RWM approaches. These acceptable trajectories were more likely to lie superiorly within the facial recess for insertion via the round window, and inferiorly for insertion via cochleostomy. Cochleostomy insertions required a greater degree of preparation and skeletonisation of the junction of the facial nerve and chorda tympani within the facial recess. The width of the virtual electrode had only marginal impact on the availability of acceptable trajectories. Heatmaps emphasised the intimate relationship the acceptable trajectories have with the facial nerve and chorda tympani. Conclusion These findings highlight the differences in the acceptable straight-line trajectories for electrodes when implanted via the round window or cochleostomy. There were notable exceptions to both surgical approaches, likely explained by the variation of hook region anatomy. The methodology used in this study holds promise for translation to patient specific surgical planning.Keywords
This publication has 43 references indexed in Scilit:
- Evaluation of round window accessibility to cochlear implant insertionEuropean Archives of Oto-Rhino-Laryngology, 2012
- Development and evaluation of the modiolar research array – multi-centre collaborative study in human temporal bonesCochlear Implants International, 2011
- Can Virtual reality simulator be used as a training aid to improve cadaver temporal bone dissection? Results of a randomized blinded control trialThe Laryngoscope, 2011
- Differentiating levels of surgical experience on a virtual reality temporal bone simulatorOtolaryngology–Head and Neck Surgery, 2010
- Optimal Cochlear Implant Insertion VectorsOtology & Neurotology, 2010
- Variational Anatomy of the Human CochleaOtology & Neurotology, 2009
- Role of Electrode Placement as a Contributor to Variability in Cochlear Implant OutcomesOtology & Neurotology, 2008
- Scala Tympani Cochleostomy I: Results of a SurveyThe Laryngoscope, 2007
- Comparison of Round Window and Cochleostomy Approaches with a Prototype Hearing Preservation ElectrodeAudiology and Neurotology, 2006
- Preservation of Basal Inner Ear Structures in Cochlear ImplantationORL, 2004