A Modified Transfemoral Approach Using Modular Cementless Revision Stems
Authors:
- Bernd FinkBFBernd Fink
- Alexandra GrossmannAGAlexandra Grossmann
- Svenja SchubringSSSvenja Schubring
- Martin S SchulzMSMartin S Schulz
- Martin FuerstMFMartin Fuerst
- 1 September 2007
- journal article
- clinical trial
- Published by Wolters Kluwer Health in Clinical Orthopaedics and Related Research
- Vol. 462, 105-114
Abstract
The transfemoral approach in its traditional form, using a nonmodular Wagner self-locking revision stem, has the disadvantages of a less predictable union rate of the bony flap and a high rate of stem subsidence. To investigate whether this situation can be improved by using a modified transfemoral approach and modular curved cementless revision stems, we prospectively analyzed 68 hip revisions and followed them clinically and radiographically for a minimum of 24 months (mean +/- standard deviation, 32.4 +/- 11.2 months). One year after the operation, the osteotomy showed bony consolidation in all but one case (98.5%). We noted subsidence in six cases (8.8%) and two of these stems became loose. In all of these cases, the circular fixation zone of the stem in the isthmus of the femur was less than 3 cm. The Harris hip score improved continuously from 41.4 +/- 14.5 points preoperatively to 85.9 +/- 14.6 points 24 months postoperatively. The modified transfemoral approach in combination with a curved, modular revision stem showed reproducibly good results concerning union of the bony flap and subsidence of the stem if the fixation zone was not less than 3 cm.Keywords
This publication has 44 references indexed in Scilit:
- Femoral Revision With a Fluted, Tapered, Modular StemThe Journal of Arthroplasty, 2006
- Anterior Windowing of the Femur Diaphysis for Cement Removal in Revision SurgeryClinical Orthopaedics and Related Research, 2005
- Extended Femoral Osteotomy for Revision of Hip ArthroplastyThe Journal of Arthroplasty, 2005
- Exposure for RevisionClinical Orthopaedics and Related Research, 2004
- Das zementfreie diaphysäre Verankerungsprinzip für den Hüftschaftwechsel bei großen Knochendefekten - Analyse von 12 Jahren Erfahrung mit dem Wagner-RevisionsschaftZeitschrift für Orthopädie und ihre Grenzgebiete, 2001
- Uncemented Revision Total Hip ArthroplastyClinical Orthopaedics and Related Research, 1996
- Failure of a proximally porous-coated femoral prosthesis in revision total hip arthroplastyThe Journal of Arthroplasty, 1995
- Extended proximal femoral osteotomyThe Journal of Arthroplasty, 1995
- Femur-RevisionsprotheseZeitschrift für Orthopädie und ihre Grenzgebiete, 1993
- Controlled PerforationClinical Orthopaedics and Related Research, 1990