Novel sequential separation and determination of a quaternary mixture of fungicides by using an automatic fluorimetric optosensor
- 16 January 2019
- journal article
- research article
- Published by Taylor & Francis in Food Additives & Contaminants: Part A
- Vol. 36 (2) , 278-288
Abstract
A versatile flow-through multi-optosensor is proposed for the separation and spectrofluorimetric determination of mixtures of four widely used pesticides: carbendazim, thiabendazole, carbaryl and o-phenylphenol at µg g−1 levels in fruits. The flow system is based on the online pre-concentration and separation of the pesticides on a solid sensing microzone, followed by the sequential measurement of their native fluorescence. The separation of the pesticides takes place on a solid support located in the same flow cell, on which analytes are temporarily immobilized and separated from the matrix due to their different retention/desorption kinetics when they interact with the C18 silica gel microbeads. Suitable analytical parameters were obtained for the selected analytes, with method detection and quantification limits ranging between 0.1–0.5 and 0.2–1.6 µg g−1, respectively. These values comply with the maximum residue limits (MRLs) established by the Codex Alimentarius for these commodities; in addition, carbendazim, thiabendazole and ortho-phenylphenol comply with the MRLs of The European Union. The developed method was applied to the analysis of citrus fruits by performing recovery studies. Recoveries between 85% and 115% were obtained in all cases, and the results were confirmed by a liquid chromatography–mass spectrometry reference method.Keywords
Funding Information
- Ministerio de Economía y Competitividad (CTQ2016-7511-R)
This publication has 31 references indexed in Scilit:
- Automated solid-phase spectrophotometric system for optosensing of bromate in drinking watersAnalytical Methods, 2012
- Trends in flow-based analytical methods applied to pesticide detection: A reviewAnalytica Chimica Acta, 2011
- Multiresidue Analysis of Pesticides in Vegetables and Citrus Fruits by LC–MS–MSChromatographia, 2010
- Chemiluminescence based technique for the detection of methyl parathion in water and fruit beveragesAnalytical Methods, 2010
- Flow-through optosensor combined with photochemically induced fluorescence for simultaneous determination of binary mixtures of sulfonamides in pharmaceuticals, milk and urineAnalytica Chimica Acta, 2007
- Determination of azoxystrobin residues in grapes, musts and wines with a multicommuted flow-through optosensor implemented with photochemically induced fluorescenceAnalytica Chimica Acta, 2007
- Multicommuted fluorescence based optosensor for the screening of bitertanol residues in banana samplesFood Chemistry, 2007
- Development of a multicommuted flow-through optosensor for the determination of a ternary pharmaceutical mixtureJournal of Pharmaceutical and Biomedical Analysis, 2006
- Pesticide residues survey in citrus fruitsFood Additives & Contaminants, 2005
- A facile flow-through phosphorimetric sensing device for simultaneous determination of naptalam and its metabolite 1-naphthylamineAnalytica Chimica Acta, 2004