Purpose Distal radius fractures (DRFs) represent up to 18% of all fractures in the elderly population, yet studies on the rate of complications following surgery are lacking in the literature. This systematic review aimed to quantify the rate of complications and reinterventions in patients treated with volar plate for distal radius fractures, and analyze if there was any predisposing factor. Methods A comprehensive literature search was performed on three databases up to January 2023, following PRISMA guidelines. Studies describing volar plate complications and hardware removal were included. A systematic review was performed on complications and rate of reintervention. Assessment of risk of bias and quality of evidence was performed with the ‘Down and Black’s Checklist for measuring quality’. Results About112 studies including 17 288 patients were included. The number of complications was 2434 in 2335 patients; the most frequent was carpal tunnel syndrome (CTS), representing 14.3% of all complications. About 104 studies reported the number of reinterventions, being 1880 with a reintervention rate of 8.5%. About 84 studies reported the reason of reintervention; the most common were patient’s will (3.0%), pain (1.1%), CTS (1.2%), and device failure (1.1%). Conclusion The complication rate after DRFs is 13.5%, with the main complication being CTS (14.3%), followed by pain and tendinopathy. The reintervention rate is 8.5%, mainly due to the patient’s willingness, and all these patients had plate removal. Correct positioning of the plate and correct information to the patient before surgery can reduce the number of hardware removal, thereby reducing costs and the risk of complications associated with VLP for distal radius fractures. Abstract Purpose Distal radius fractures (DRFs) represent up to 18% of all fractures in the elderly population, yet studies on the rate of complications following surgery are lacking in the literature. This systematic review aimed to quantify the rate of complications and reinterventions in patients treated with volar plate for distal radius fractures, and analyze if there was any predisposing factor. Methods A comprehensive literature search was performed on three databases up to January 2023, following PRISMA guidelines. Studies describing volar plate complications and hardware removal were included. A systematic review was performed on complications and rate of reintervention. Assessment of risk of bias and quality of evidence was performed with the ‘Down and Black’s Checklist for measuring quality’. Results About112 studies including 17 288 patients were included. The number of complications was 2434 in 2335 patients; the most frequent was carpal tunnel syndrome (CTS), representing 14.3% of all complications. About 104 studies reported the number of reinterventions, being 1880 with a reintervention rate of 8.5%. About 84 studies reported the reason of reintervention; the most common were patient’s will (3.0%), pain (1.1%), CTS (1.2%), and device failure (1.1%). Conclusion The complication rate after DRFs is 13.5%, with the main complication being CTS (14.3%), followed by pain and tendinopathy. The reintervention rate is 8.5%, mainly due to the patient’s willingness, and all these patients had plate removal. Correct positioning of the plate and correct information to the patient before surgery can reduce the number of hardware removal, thereby reducing costs and the risk of complications associated with VLP for distal radius fractures.Keywords
This publication has 124 references indexed in Scilit:
- Prospective Study of Distal Radius Fractures Treated With a Volar Locking Plate SystemThe Journal of Hand Surgery, 2008
- GRADE: an emerging consensus on rating quality of evidence and strength of recommendationsBMJ, 2008
- Results of Dorsal or Volar Plate Fixation of AO Type C3 Distal Radius Fractures: A Retrospective StudyThe Journal of Hand Surgery, 2007
- Complications Following Internal Fixation of Unstable Distal Radius Fracture With a Palmar Locking-PlateJournal of Orthopaedic Trauma, 2007
- Surgical treatment of distal radius fractures with an angle fixed bar palmar plating system: a single center study of 102 patients over a 2-year periodArchives of orthopaedic and trauma surgery, 2006
- Functional Outcome and Complications After Volar Plating for Dorsally Displaced, Unstable Fractures of the Distal RadiusThe Journal of Hand Surgery, 2006
- A Randomized Prospective Study on the Treatment of Intra-Articular Distal Radius Fractures: Open Reduction and Internal Fixation With Dorsal Plating Versus Mini Open Reduction, Percutaneous Fixation, and External FixationThe Journal of Hand Surgery, 2005
- Functional outcome of unstable distal radius fractures: ORIF with a volar fixed-angle tine plate versus external fixationThe Journal of Hand Surgery, 2005
- THE TREATMENT OF UNSTABLE DISTAL RADIUS FRACTURES WITH VOLAR FIXATIONHand Surgery, 2000
- The feasibility of creating a checklist for the assessment of the methodological quality both of randomised and non-randomised studies of health care interventions.Journal of Epidemiology and Community Health, 1998