Heparin solution in the prevention of occlusions in Hickman® catheters a randomized clinical trial
Open Access
- 1 January 2021
- journal article
- research article
- Published by FapUNIFESP (SciELO) in Revista Latino-Americana de Enfermagem
- Vol. 29, e3385
Abstract
Objective: to evaluate the effectiveness of the 50 IU/mL heparin solution compared to the 0.9% isotonic saline solution in preventing occlusion of the double lumen Hickman® catheter, 7 and 9 French, in patients undergoing hematopoietic stem cell transplantation. Method: a triple-blind randomized clinical trial. 17 double-lumen catheters (heparin group: n=7 and 0.9% isotonic saline group: n=10) were analyzed in which the two catheter routes were evaluated separately, totaling 34 lumens. The outcome variables were occlusion without reflux and complete occlusion. Descriptive analyses were performed using the Chi-square test and, of survival, according to the Kaplan-Meier test. Results: the mean number of days until the occlusion outcome was 52 in the heparin group and 13.46 in the 0.9% isotonic saline group in the white catheter route (p<0.001). In the red route, the mean follow-up days in the heparin group were 35.29, with no occlusion and 22.30 in the 0.9% isotonic saline group until the first occlusion (p=0.030). Conclusion: blocking with 50 IU/mL heparin solution is more effective than 0.9% isotonic saline in preventing occlusion of the Hickman® catheter. Brazilian Registry of Clinical Trials: RBR-3ht499.Keywords
This publication has 17 references indexed in Scilit:
- Heparin versus 0.9% sodium chloride intermittent flushing for the prevention of occlusion in long term central venous catheters in infants and childrenCochrane Database of Systematic Reviews, 2015
- Comparison of the Effects of Heparin and 0.9% Sodium Chloride Solutions in Maintenance of Patency of Central Venous CathetersAnesthesiology and Pain Medicine, 2015
- Heparin versus 0.9% sodium chloride intermittent flushing for prevention of occlusion in central venous catheters in adultsCochrane Database of Systematic Reviews, 2014
- Flushing the Central Venous Catheter: Is Heparin Necessary?The Journal of Vascular Access, 2014
- Comparing normal saline versus diluted heparin to lock non-valved totally implantable venous access devices in cancer patients: a randomised, non-inferiority, open trialAnnals of Oncology, 2013
- Central Venous Catheter Care for the Patient With Cancer: American Society of Clinical Oncology Clinical Practice GuidelineJournal of Clinical Oncology, 2013
- Efficacy of Normal Saline Versus Heparinized Saline Solution for Locking Catheters of Totally Implantable Long-Term Central Vascular Access Devices in Adult Cancer PatientsCancer Nursing, 2012
- Prospective, Randomized Trial of Two Different Modalities of Flushing Central Venous Catheters in Pediatric Patients With CancerJournal of Clinical Oncology, 2009
- Estudio comparativo del mantenimiento de la permeabilidad de los catéteres venosos centrales de tres lucesEnfermería Intensiva, 2007
- Keeping central venous lines open: a prospective comparison of heparin, vitamin C and sodium chloride sealing solutions in medical patientsIntensive Care Medicine, 2002