Comparison of the Effects of High-Power Diode Laser and Electrocautery for Lingual Frenectomy in Infants: A Blinded Randomized Controlled Clinical Trial
Authors:
- Adriana MazzoniAMAdriana Mazzoni
- Ricardo Scarparo NavarroRNRicardo Scarparo Navarro
- Kristianne Porta Santos FernandesKFKristianne Porta Santos Fernandes
- Raquel Agnelli Mesquita-FerrariRMRaquel Agnelli Mesquita-Ferrari
- Anna Carolina Ratto Tempestini HorlianaAHAnna Carolina Ratto Tempestini Horliana
- Tamiris SilvaTSTamiris Silva
- Elaine Marcílio SantosESElaine Marcílio Santos
- Ana Paula Taboada SobralASAna Paula Taboada Sobral
- Aldo Brugnera JúniorAJAldo Brugnera Júnior
- Samir NammourSamir Nammour
- Lara Jansinski MottaLMLara Jansinski Motta
- Sandra Kalil BussadoriSBSandra Kalil Bussadori
Open Access
- 30 June 2022
- journal article
- research article
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 11 (13) , 3783
Abstract
The aim of the study was to evaluate the release of the lingual frenulum through frenectomy in newborns zero to 90 days of age who breastfed and had diagnosis of ankyloglossia with an indication for surgery, comparing two methods: electrocautery and a high-power diode laser. Fifty-seven patients were randomly allocated to two groups (23 submitted to electrocautery and 34 submitted to a high power diode laser). Tongue movements were evaluated based on a clinical assessment and using the Bristol Tongue Assessment Tool (BTAT) before and 15 days after the surgical procedures. The visual analog scale was administered to the mothers on the same occasions for the measurement of pain during breastfeeding. Both groups had an increased BTAT score (favorable outcome) at the post-surgical evaluation, but the anterior third of the tongue was not always free to enable the movements necessary for lingual functions. It is fundamental for surgeons to have skill and in-depth knowledge of the equipment used to avoid accidents and complications in the region of important structures. Both techniques employed in this study were safe and effective, causing little bleeding and few postoperative complications. The group submitted to a high-power diode laser exhibited less post-surgical bleeding compared to the group submitted to electrocautery and no inflammation at the edges of the surgical cut.Keywords
Funding Information
- Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (88887.494956/2020-00)
This publication has 22 references indexed in Scilit:
- Breastfeeding improvement following tongue‐tie and lip‐tie release: A prospective cohort studyThe Laryngoscope, 2016
- Evaluation of Patient Perceptions After Vestibuloplasty Procedure: A Comparison of Diode Laser and Scalpel TechniquesJournal of Clinical and Diagnostic Research, 2016
- Diode laser surgery versus scalpel surgery in the treatment of fibrous hyperplasia: a randomized clinical trialInternational Journal of Oral and Maxillofacial Surgery, 2015
- Processo reparacional em tecido cutâneo e oral de ratos submetidos à incisão cirúrgica com lasers de CO2 e diodo, e com bisturi elétrico e convencional. Uma análise morfométrica2015
- The development of a tongue assessment tool to assist with tongue-tie identificationArchives of Disease in Childhood - Fetal and Neonatal Edition, 2015
- Surgical techniques for the treatment of ankyloglossia in children: a case seriesJournal of Applied Oral Science, 2014
- Comparison of Diode Laser and Er:YAG Lasers in the Treatment of AnkyloglossiaPhotomedicine and Laser Surgery, 2010
- Análise da dose do laser de baixa potência em equipamentos nacionaisBrazilian Journal of Physical Therapy, 2008
- Cicatrização de feridasABCD. Arquivos Brasileiros de Cirurgia Digestiva (São Paulo), 2007
- Evaluation of Patient Perceptions After Frenectomy Operations: A Comparison of Carbon Dioxide Laser and Scalpel TechniquesJournal of Periodontology, 2006