Nonconvex prior image constrained compressed sensing (NCPICCS): Theory and simulations on perfusion CT
Authors:
- J. TrzaskoJTJ. Trzasko
- S. LengSLS. Leng
- L. YuLYL. Yu
- A. ManducaAMA. Manduca
- C. H. McColloughCMC. H. McCollough
- 28 March 2011
- journal article
- research article
- Published by Wiley in Medical Physics
- Vol. 38 (4) , 2157-2167
Abstract
Purpose:: To present and evaluate a new image reconstruction method for dynamic CT based on a nonconvex prior image constrained compressed sensing (NCPICCS) algorithm. The authors systematically compared the undersampling potential, functional information recovery, and solution convergence speed of four compressed sensing (CS) based image reconstruction methods using perfusion CT data: Standard ‐based CS, nonconvex CS (NCCS), and ‐based and nonconvex CS, including an additional constraint based on a prior image (PICCS and NCPICCS, respectively).Methods:: The Shepp–Logan phantom was modified such that its uppermost ellipses changed attenuation through time, simulating both an arterial input function (AIF) and a homogeneous tissue perfusion region. Data were simulated with and without Poisson noise added to the projection data and subsequently reconstructed with all four CS‐based methods at four levels of undersampling: 20, 12, 6, and 4 projections. Root mean squared (RMS) error of reconstructed images and recovered time attenuation curves (TACs) were assessed as well as convergence speed. The performance of both PICCS and NCPICCS methods were also evaluated using a kidney perfusion animal experiment data set.Results:: All four CS‐based methods were able to reconstruct the phantoms with 20 projections, with similar results on the RMS error of the recovered TACs. NCCS allowed accurate reconstructions with as few as 12 projections, PICCS with as few as six projections, and NCPICCS with as few as four projections. These results were consistent for noise‐free and noisy data. NCPICCS required the fewest iterations to converge across all simulation conditions, followed by PICCS, NCCS, and then CS. On animal data, at the lowest level of undersampling tested (16 projections), the image quality of NCPICCS was better than PICCS with fewer streaking artifacts, while the TAC accuracy on the selected region of interest was comparable.Conclusions:: The authors have presented a novel method for image reconstruction using highly undersampled dynamic CT data. The NCPICCS method takes advantage of the information provided by a prior image, as in PICCS, but employs a more general nonconvex sparsity measure [such as the ‐norm ] rather than the conventional convex ‐norm. Despite the lack of guarantees of a globally optimal solution, the proposed nonconvex extension of PICCS consistently allowed for image reconstruction from fewer samples than the analogous ‐based PICCS method. Both nonconvex sparsity measures as well as prior image information (when available) significantly reduced the number of iterations required for convergence, potentially providing computational advantages for practical implementation of CS‐based image reconstruction techniques.Keywords
Funding Information
- National Institutes of Health (R018898)
This publication has 42 references indexed in Scilit:
- Perfusion measurements by micro-CT using prior image constrained compressed sensing (PICCS): initial phantom resultsPhysics in Medicine & Biology, 2010
- Why do commercial CT scanners still employ traditional, filtered back-projection for image reconstruction?Inverse Problems, 2009
- Renal Perfusion and Hemodynamics: Accurate in Vivo Determination at CT with a 10-Fold Decrease in Radiation Dose and HYPR Noise ReductionRadiology, 2009
- Performance comparison between total variation (TV)-based compressed sensing and statistical iterative reconstruction algorithmsPhysics in Medicine & Biology, 2009
- In Defense of Body CTAmerican Journal of Roentgenology, 2009
- Radiation dose reduction in time-resolved CT angiography using highly constrained back projection reconstructionPhysics in Medicine & Biology, 2009
- Compressed sensing based interior tomographyPhysics in Medicine & Biology, 2009
- Strategies for Reducing Radiation Dose in CTRadiologic Clinics of North America, 2009
- High temporal resolution and streak-free four-dimensional cone-beam computed tomographyPhysics in Medicine & Biology, 2008
- Image reconstruction in circular cone-beam computed tomography by constrained, total-variation minimizationPhysics in Medicine & Biology, 2008