A critique of the apneic oxygenation test for the diagnosis of “brain death”
- 1 January 2010
- journal article
- review article
- Published by Wolters Kluwer Health in Pediatric Critical Care Medicine
- Vol. 11 (4) , 475-8
Abstract
To determine the reliability and safety of the apneic oxygenation test to diagnose brain death for the purpose of organ donation. Published scientific literature in Medline database, organ donation guidelines and neurophysiological principles described in medical textbooks. Articles on brain death, apnea testing, and radionuclide scintigraphy. Hypercarbia with a target Paco2 of 60 mm Hg (8.0 kPa) must be reached before apnea is deemed consistent with brain death in some clinical guidelines, whereas a level of 50 mm Hg (6.7 kPa) is required in another. However, the sensitivity and specificity of the test are doubtful because some patients have commenced spontaneous respiration >60 mm Hg (8.0 kPa) and high levels of Paco2 may cause CO2 narcosis. Furthermore, the test may be harmful if the brain stem is responsive because hypercarbia may also cause intracranial hypertension and contribute to brain damage. Although guidelines for organ donation recommend the test as an essential component of brain death diagnosis, it is often not performed or performed inadequately. Wide variation in conduct of the test has prompted calls for standardization. : The apneic oxygenation test is unreliable in the diagnosis of brain death. It is scientifically flawed and hypothesized to cause brain death. In lieu of this test, a reliable test of brain perfusion should be mandatory, whereas the apneic oxygenation test, if performed at all, should be restricted to demonstration of apnea after brain perfusion has been shown to be absent.Keywords
This publication has 57 references indexed in Scilit:
- Pronouncing brain deathNeurology, 2008
- An evaluation of capnography monitoring during the apnoea test in brain-dead patientsEuropean Journal of Anaesthesiology, 2007
- Efficacy of a T-piece system and a continuous positive airway pressure system for apnea testing in the diagnosis of brain death*Critical Care Medicine, 2006
- Severe brain injury to neurological determination of death: Canadian forum recommendationsCanadian Medical Association Journal, 2006
- Apnea testing for the diagnosis of brain deathActa Neurologica Scandinavica, 2005
- The Diagnosis of Brain DeathNew England Journal of Medicine, 2001
- Altered Apnea Threshold in a Child With Suspected Brain DeathJournal of Child Neurology, 1995
- Cerebral blood flow, vasoreactivity, and oxygen consumption during barbiturate therapy in severe traumatic brain lesionsJournal of Neurosurgery, 1988
- Book ReviewPediatric Intensive CareNew England Journal of Medicine, 1988
- Brain DeathNew England Journal of Medicine, 1978