Abstract
Purpose: To evaluate prospective motion correction using the pilot tone (PT) as a quantitative respiratory motion signal with high temporal resolution for cardiac cine images during free breathing.Methods: Before cine data acquisition, a short prescan was performed, calibrating the PT to the respiratory‐induced heart motion using respiratory‐resolved real‐time images. The calibrated PT was then applied for nearly real‐time prospective motion correction of cine MRI through slice tracking (ie, updating the slice position before every readout). Additionally, in‐plane motion correction was performed retrospectively also based on the calibrated PT data. The proposed method was evaluated in a moving phantom and 10 healthy volunteers.Results: The PT showed very good correlation to the phantom motion. In volunteer studies using a long‐term scan over 7.96 ± 1.40 min, the mean absolute error between registered and predicted motion from the PT was 1.44 ± 0.46 mm in head‐feet and 0.46 ± 0.07 mm in anterior‐posterior direction. Irregular breathing could also be corrected well with the PT. The PT motion correction leads to a significant improvement of contrast‐to‐noise ratio by 68% (P ≤ .01) between blood pool and myocardium and sharpness of endocardium by 24% (P = .04) in comparison to uncorrected data. The image score, which refers to the cine image quality, has improved with the utilization of the proposed PT motion correction.Conclusion: The proposed approach provides respiratory motion‐corrected cine images of the heart with improved image quality and a high scan efficiency using the PT. The PT is independent of the MR acquisition, making this a very flexible motion‐correction approach.Keywords
This publication has 34 references indexed in Scilit:
- Respiratory motion models: A reviewMedical Image Analysis, 2013
- Respiratory bellows revisited for motion compensation: Preliminary experience for cardiovascular MRMagnetic Resonance in Medicine, 2010
- Acoustic cardiac triggering: a practical solution for synchronization and gating of cardiovascular magnetic resonance at 7 TeslaJournal of Cardiovascular Magnetic Resonance, 2010
- High spatial and temporal resolution cardiac cine MRI from retrospective reconstruction of data acquired in real time using motion correction and resortingMagnetic Resonance in Medicine, 2009
- 2D free‐breathing dual navigator‐gated cardiac function validated against the 2D breath‐hold acquisitionJournal of Magnetic Resonance Imaging, 2008
- Whole‐heart cine MRI using real‐time respiratory self‐gatingMagnetic Resonance in Medicine, 2007
- Magnetic resonance imaging of freely moving objects: prospective real-time motion correction using an external optical motion tracking systemNeuroImage, 2006
- Matrix description of general motion correction applied to multishot imagesMagnetic Resonance in Medicine, 2005
- SENSE: Sensitivity encoding for fast MRIMagnetic Resonance in Medicine, 1999
- Respiratory Motion of the Heart: Kinematics and the Implications for the Spatial Resolution in Coronary ImagingMagnetic Resonance in Medicine, 1995