Preparation and Optimization of Optical pH Sensor Based on Sol-Gel
Open Access
Abstract
Making use of the sol-gel technique, an optical pH sensor was prepared, which was made from an organic carrier with four indictors including congo red, bromophenol blue, cresol red, and chlorophenol red, cross-linked by tetraethyl orthosilicate (TEOS) and cellulose acetate. The actual detection range of the optical pH sensor is 2.5–11.0. The optimal ratio of ethyl orthosilicate, absolute ethanol, deionized water, and hydrochloric acid in glue precursor of the sensor-sensitive membrane was explored. The orthogonal experiment was designed to optimize the dosage of cellulose acetate, N,N-dimethylformamide (DMF), indicator, hydrochloric acid, and precursor glue in preparing the sensor-sensitive membrane. The linearity, measurement accuracy, repeatability, stability, and response time of the prepared pH sensor were tested. The measurement results were analyzed using a support vector machine and linear regression. The experimental results show that the optical pH sensor has a measurement accuracy of up to 0.2 pH and better stability and repeatability than the traditional pH glass electrode.Keywords
Funding Information
- National Natural Science Foundation of China (U1609205)
- Zhejiang Province Public Welfare Technology Application Research Project (2017C33074)
This publication has 22 references indexed in Scilit:
- No-core fiber-based highly sensitive optical fiber pH sensorJournal of Biomedical Optics, 2017
- An internal reference fluorescent pH sensor with two pH-sensitive fluorophores carrierSensors and Actuators B: Chemical, 2016
- Effect of UV irradiation on the aggregation of TiO2 in an aquatic environment: Influence of humic acid and pHEnvironmental Pollution, 2016
- Effects of water pH and proteinase K treatment on the yield of environmental DNA from water samplesLimnology, 2016
- Development of a pH sensor based on a nanostructured filter adding pH-sensitive fluorescent dye for detecting acetic acid in photovoltaic modulesJapanese Journal of Applied Physics, 2015
- Novel pH microsensor based on a thin film gold electrode modified with lead dioxide nanoparticlesMicrochimica Acta, 2014
- Effect of substrate concentration and pH on biohydrogen production kinetics from food industry wastewater by mixed cultureInternational Journal of Hydrogen Energy, 2013
- Development of the Glass Electrode and the pH ResponseJournal of Chemical Education, 2013
- A Ratiometric CdSe/ZnS Nanocrystal pH SensorJournal of the American Chemical Society, 2006
- The use of glass electrodes for the measurement of activities of metal ionsRecueil des Travaux Chimiques des Pays-Bas, 1952