Abstract
The use of buffer solutions is immensely important in a great variety of disciplines. The generation of continuous pH gradients in flow systems plays an important role in the chromatographic separation of proteins, high-throughput pKa determinations, etc. We demonstrate here that electrodialytic membrane suppressors used in ion chromatography can be used to generate buffers. The generated pH, computed from first principles, agrees well with measured values. We demonstrate the generation of phosphate and citrate buffers using a cation-exchange membrane (CEM) -based anion suppressor and Tris and ethylenediamine buffers using an anion-exchange membrane (AEM) -based cation suppressor. Using a mixture of phosphate, citrate, and borate as the buffering ions and using a CEM suppressor, we demonstrate the generation of a highly reproducible (avg RSD 0.20%, n = 3), temporally linear (pH 3.0–11.9, r2 > 0.9996), electrically controlled pH gradient. With butylamine and a large concentration (0.5 M) of added NaCl, we demonstrate a similar linear pH gradient of large range with a near-constant ionic strength. We believe that this approach will be of value for the generation of eluents in the separation of proteins and other biomolecules and in online process titrations.Keywords
This publication has 52 references indexed in Scilit:
- Phosphate-buffered saline-based nucleofection of primary endothelial cellsAnalytical Biochemistry, 2009
- Reagentless pH-stat for Microliter Fluid SpecimensAnalytical Chemistry, 2008
- Challenges and Constraints of Using Oxygen Cathodes in Microbial Fuel CellsEnvironmental Science & Technology, 2006
- HPLC Determination of Cyanuric Acid in Swimming Pool Waters Using Phenyl and Confirmatory Porous Graphitic Carbon ColumnsAnalytical Chemistry, 2001
- Lewis-Acid Catalyzed Organic Reactions in Water. The Case of AlCl3, TiCl4, and SnCl4 Believed To Be Unusable in Aqueous MediumThe Journal of Organic Chemistry, 2001
- Dynamic On-Column pH Monitoring in Capillary Electrophoresis: Application to Volume-Limited Outlet VialsAnalytical Chemistry, 1996
- Influence of alkaline buffers on cytoplasmic pH in myocardial cells exposed to metabolic acidosisResuscitation, 1996
- The effects of buffer salt concentration on the HPLC retention of nucleic acid componentsChromatographia, 1989
- Electrochemical pH-stat and controlled current coulometric acid-base analyzerAnalytical Chemistry, 1976
- Self-Equilibrating Electrolytic Method for Determination of Acid Production RatesAnalytical Chemistry, 1956