Serotonin measurement by lab-on-a–contact lens in porcine and human tears
- 16 September 2026
- journal article
- research article
- Published by American Association for the Advancement of Science (AAAS) in Science Translational Medicine
- Vol. 18 (867)
Abstract
Stress-related endocrine responses are critical for understanding human performance and mental health. Conventional assessments rely heavily on subjective self-report questionnaires or invasive sampling such as venipuncture. Tears offer a noninvasive source of neurochemical biomarkers, including serotonin, a key regulator of stress and mood. However, real-time and continuous monitoring of tear serotonin has not yet been fully realized. Here, we present a reversible lab-on-a–contact lens platform that integrates a printable, stretchable ferrocene-based electrochemical sensor for in situ detection of serotonin in tear fluid. The device is fabricated on a soft hydrogel lens and uses an electrochemically refreshable redox surface to restore baseline between measurements. Calibration in artificial tears established a limit of detection of 72 picomolar and a dynamic range of 0.1 to 500 nanomolar. Function was maintained for more than 28 days in a tear-like environment and under repeated mechanical deformations (flipping, folding, stretching, and twisting), with stability confirmed by periodic redox cycling. Ocular safety and biocompatibility were demonstrated in a porcine eye model. In a chronic stress mouse model, tear serotonin concentrations inversely correlated with cortisol in both serum and tears, and a first-in-human pilot study further supported the relationship between tear serotonin and stress with off-line analysis by the lab-on-a–contact lens platform. This platform could enable applications in decentralized, noninvasive endocrine monitoring and holds promise as a clinically translatable tool for real-time mental health biomarker assessment.Keywords
Funding Information
- Brain and Behavior Research Foundation (32583)
- Terasaki Institute for Biomedical Innovation
This publication has 100 references indexed in Scilit:
- Intraocular Pressure Monitoring Smart Contact Lens with High Environmental StabilityAdvanced Functional Materials, 2024
- A Microfluidic Contact Lens to Address Contact Lens‐Induced Dry EyeSmall, 2022
- Real-time monitoring of 5-HT release from cells based on MXene hybrid single-walled carbon nanotubes modified electrodeAnalytical and Bioanalytical Chemistry, 2022
- Wireless Non‐Invasive Monitoring of Cholesterol Using a Smart Contact LensAdvanced Science, 2022
- A Microchambers Containing Contact Lens for the Noninvasive Detection of Tear ExosomesAdvanced Functional Materials, 2022
- Lab‐on‐a‐Contact Lens: Recent Advances and Future Opportunities in Diagnostics and TherapeuticsAdvanced Materials, 2022
- Bimetallic Nanocatalysts Immobilized in Nanoporous Hydrogels for Long‐Term Robust Continuous Glucose Monitoring of Smart Contact LensAdvanced Materials, 2022
- Electronic Contact Lens: A Platform for Wireless Health Monitoring ApplicationsAdvanced Intelligent Systems, 2020
- 3-Aminopropyl-triethoxysilane Functionalized Graphene Oxide: A Highly Efficient and Recyclable Catalyst for Knoevenagel CondensationCatalysis Letters, 2014
- Clinical biochemistry of tearsSurvey of Ophthalmology, 1981