Investigation of analytical variation in metabonomic analysis using liquid chromatography/mass spectrometry
- 6 August 2007
- journal article
- research article
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 21 (18) , 2965-2970
Abstract
Sources of analytical variation in high‐performance liquid chromatography/mass spectrometry (HPLC/MS), such as changes in retention, mass accuracy or signal intensity, have been investigated to assess their importance as a variable in the metabonomic analysis of human urine. In this study chromatographic retention and mass accuracy were found to be quite reproducible with the most significant source of analytical variation in the data sets obtained being the result of changes in detector response. Depending on the signal intensity threshold used to define the presence of a peak a sample component could be present in some replicate injections and absent in others within the same run. The implementation of a more sophisticated data software analysis package was found to greatly reduce the impact of detector response variability resulting in improved data analysis. Copyright © 2007 John Wiley & Sons, Ltd.Keywords
This publication has 15 references indexed in Scilit:
- Evaluation of Matrix Effects in Metabolite Profiling Based on Capillary Liquid Chromatography Electrospray Ionization Quadrupole Time-of-Flight Mass SpectrometryAnalytical Chemistry, 2007
- Chemometrics Techniques for Metabonomics2007
- Chemometrics in MetabonomicsJournal of Proteome Research, 2006
- Analytical Strategies in MetabonomicsJournal of Proteome Research, 2006
- A pragmatic and readily implemented quality control strategy for HPLC-MS and GC-MS-based metabonomic analysisThe Analyst, 2006
- Assessment of Analytical Reproducibility of 1H NMR Spectroscopy Based Metabonomics for Large-Scale Epidemiological Research: the INTERMAP StudyAnalytical Chemistry, 2006
- Metabonomics and Biomarker Discovery: LC−MS Metabolic Profiling and Constant Neutral Loss Scanning Combined with Multivariate Data Analysis for Mercapturic Acid AnalysisAnalytical Chemistry, 2005
- Large-Scale Human Metabolomics Studies: A Strategy for Data (Pre-) Processing and ValidationAnalytical Chemistry, 2005
- Metabonomics, dietary influences and cultural differences: a 1H NMR-based study of urine samples obtained from healthy British and Swedish subjectsJournal of Pharmaceutical and Biomedical Analysis, 2004
- Physiological variation in metabolic phenotyping and functional genomic studies: use of orthogonal signal correction and PLS‐DAFEBS Letters, 2002