The effect of the offset humeral head on the micromovement of pegged glenoid components
Authors:
Open Access
- 1 June 2009
- journal article
- research article
- Published by British Editorial Society of Bone & Joint Surgery in The Journal of Bone and Joint Surgery. British volume
- Vol. 91 (6) , 757-761
Abstract
In a prospective study between 2000 and 2005, 22 patients with primary osteoarthritis of the shoulder had a total shoulder arthroplasty with a standard five-pegged glenoid component, 12 with non-offset humeral head and ten with offset humeral head components. Over a period of 24 months the relative movement of the glenoid component with respect to the scapula was measured using radiostereometric analysis. Nine glenoids needed reaming for erosion. There was a significant increase in rotation about all three axes with time (p < 0.001), the largest occurring about the longitudinal axis (anteversion-retroversion), with mean values of 3.8° and 1.9° for the non-offset and offset humeral head eroded subgroups, respectively. There was also a significant difference in rotation about the anteversion-retroversion axis (p = 0.01) and the varus-valgus (p < 0.001) z-axis between the two groups. The offset humeral head group reached a plateau at early follow-up with rotation about the z-axis, whereas the mean of the non-offset humeral head group at 24 months was three times greater than that of the offset group accounting for the highly significant difference between them.Keywords
This publication has 29 references indexed in Scilit:
- Notes on the use and interpretation of radiostereometric analysisActa Orthopaedica, 2009
- Radiographic comparison of pegged and keeled glenoid componentsJournal of Shoulder and Elbow Surgery, 2005
- Guidelines for standardization of radiostereometry (RSA) of implantsActa Orthopaedica, 2005
- Radiographic analysis of polyethylene glenoid components using modern cementing techniquesJournal of Shoulder and Elbow Surgery, 2004
- Stability of cemented all-polyethylene keeled glenoid componentsThe Journal of Bone and Joint Surgery. British volume, 2004
- Measurement of glenoid version: conventional radiographs versus computed tomography scansJournal of Shoulder and Elbow Surgery, 2003
- A research agenda for Hand TherapyJournal of Hand Therapy, 2002
- Patterns of loosening of the glenoid componentThe Journal of Bone and Joint Surgery. British volume, 2002
- A standardized method for the assessment of shoulder functionJournal of Shoulder and Elbow Surgery, 1994
- Recurrent Posterior Glenohumeral Dislocation Associated With Increased Retro version of the GlenoidClinical Orthopaedics and Related Research, 1994