Metal-on-metal hip prostheses: Correlation between debris in the synovial fluid and levels of cobalt and chromium ions in the bloodstream
- 12 October 2013
- journal article
- research article
- Published by Springer Nature in International Orthopaedics
- Vol. 38 (3) , 469-475
Abstract
Hip prostheses with metal-on-metal (MoM) coupling can release cobalt-chromium particles and ions. The aim of this work is to verify the correlation between particles in the synovial fluid and circulating ions. Forty patients were enrolled; particles from synovial fluid were analysed by SEM–EDX (Scanning Electron Microscopy-Energy Dispersion X-rays analysis) and levels of circulating Co and Cr were assayed by ICP-MS (inductively-coupled plasma mass spectrometry). In 16 cases we did not find any particles in the synovial fluid and the Co level in whole blood was 0.05–4.42 ppb; in seven with few particles the blood level was 2.2–15.6 ppb; in six cases with several particles the level was 5.0–54.3 ppb; finally, in 11 cases we isolated not only Co-Cr particles, but also Cr particles with low or absent Co and in these patients the circulating level of Co was 23.8–109.6 ppb. Co in serum and Cr level both whole blood and serum have shown a similar trend to Co; the correlation between all these values and the corresponding particles is statistically significant in all cases. Co and Cr both in serum and whole blood represents a systemic representation of the particle release at local level and can therefore be used to confirm a diagnosis and monitor the wear process of MoM articular prostheses.Keywords
This publication has 32 references indexed in Scilit:
- Detection of cobalt in synovial fluid from metal-on-metal hip prosthesis: correlation with the ion haematic levelBiomarkers, 2013
- High doses of cobalt induce optic and auditory neuropathyExperimental and Toxicologic Pathology, 2013
- Cobalt and Chromium Measurement in Patients with Metal Hip ProsthesesClinical Chemistry, 2013
- Ceramic Debris in Hip Prosthesis: Correlation Between Synovial Fluid and Joint CapsuleThe Journal of Arthroplasty, 2013
- Large‐diameter metal‐on‐metal total hip arthroplasties: A page in orthopedic history?Journal of Biomedical Materials Research Part A, 2013
- Consensus Statement “Current Evidence on the Management of Metal-on-Metal Bearings”: April 16, 2012HIP International, 2013
- Are Metal Ion Levels a Useful Trigger for Surgical Intervention?The Journal of Arthroplasty, 2012
- Cobalt metabolism and toxicology—A brief updateScience of The Total Environment, 2012
- Long-term follow-up and metal ion trend of patients with metal-on-metal total hip arthroplastyInternational Orthopaedics, 2012