Weak Value Amplification Based Optical Sensor for High Throughput Real-Time Immunoassay of SARS-CoV-2 Spike Protein
Open Access
- 8 July 2024
- journal article
- research article
- Published by MDPI AG in Biosensors
- Vol. 14 (7) , 332
Abstract
The demand for accurate and efficient immunoassays calls for the development of precise, high-throughput analysis methods. This paper introduces a novel approach utilizing a weak measurement interface sensor for immunoassays, offering a solution for high throughput analysis. Weak measurement is a precise quantum measurement method that amplifies the weak value of a system in the weak interaction through appropriate pre- and post-selection states. To facilitate the simultaneous analysis of multiple samples, we have developed a chip with six flow channels capable of conducting six immunoassays concurrently. We can perform real-time immunoassay to determine the binding characteristics of spike protein and antibody through real-time analysis of the flow channel images and calculating the relative intensity. The proposed method boasts a simple structure, eliminating the need for intricate nano processes. The spike protein concentration and relative intensity curve were fitted using the Log-Log fitting regression equation, and R2 was 0.91. Utilizing a pre-transformation approach to account for slight variations in detection sensitivity across different flow channels, the present method achieves an impressive limit of detection(LOD) of 0.85 ng/mL for the SARS-CoV-2 the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) spike protein, with a system standard deviation of 5.61. Furthermore, this method has been successfully verified for monitoring molecular-specific binding processes and differentiating binding capacities.Keywords
Funding Information
- National Natural Science Foundation of China (61975089, 62105068, JCYJ20200109110606054, KCXFZ20201221173207022)
- Science and Technology Research Program of Shenzhen City (61975089, 62105068, JCYJ20200109110606054, KCXFZ20201221173207022)
This publication has 36 references indexed in Scilit:
- Ultra-precise weak measurement-based interfacial biosensorsTalanta, 2022
- Neutralizing antibody responses to SARS-CoV-2: A population based seroepidemiological analysisIndian Journal of Medical Microbiology, 2022
- Porous Au@Pt nanoparticles with superior peroxidase-like activity for colorimetric detection of spike protein of SARS-CoV-2Journal of Colloid and Interface Science, 2021
- Temporal maturation of neutralizing antibodies in COVID-19 convalescent individuals improves potency and breadth to circulating SARS-CoV-2 variantsImmunity, 2021
- Neutralising antibody activity against SARS-CoV-2 VOCs B.1.617.2 and B.1.351 by BNT162b2 vaccinationThe Lancet, 2021
- Transmission of COVID-19 virus by droplets and aerosols: A critical review on the unresolved dichotomyEnvironmental Research, 2020
- Airborne transmission of SARS-CoV-2: The world should face the realityEnvironment International, 2020
- Clinical features of patients infected with 2019 novel coronavirus in Wuhan, ChinaThe Lancet, 2020
- Sensitive optical biosensors for unlabeled targets: A reviewAnalytica Chimica Acta, 2008
- Quantification of total sheep IgE concentration using anti-ovine IgE monoclonal antibodies in an enzyme immunoassayVeterinary Immunology and Immunopathology, 1997