A novel PWM pulse modifying method for reconstructing three-phase AC currents from DC bus currents of inverter
Authors:
- 1 November 2009
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 4, 1-6
Abstract
A novel PWM pulse modifying method for DC bus current detection has been developed to reduce acoustic noise and distortion. DC bus current detection needs wide pulse durations to reconstruct three AC currents. PWM pulse modifying methods have been proposed to expand short pulse durations at low modulation. However, harmonic currents caused by modification signals distort reconstructed currents and create a specific frequency. In this paper, several PWM modifying methods are examined. Moreover a method for modifying signals is proposed that prevents harmonic currents from distorting reconstructed currents and creating a low frequency. Simulated and experimental results show good performances of total harmonic distortion and a high frequency.Keywords
This publication has 5 references indexed in Scilit:
- A Method for Calculating AC Currents from Sampled DC Current Data in a Three-phase PWM InverterIEEJ Transactions on Industry Applications, 2007
- Phase Current Reconstruction for AC Motor Drives Using a DC Link Single Current Sensor and Measurement Voltage VectorsIEEE Transactions on Power Electronics, 2006
- Single current sensor technique in the DC link of three-phase PWM-VS inverters: a review and a novel solutionIEEE Transactions on Industry Applications, 1997
- An ideal PWM-VSI inverter using only one current sensor in the DC-link1994
- Novel current sensor for PWM AC drivesIEE Proceedings B Electric Power Applications, 1988