The poloidal correlation reflectometry diagnostic operated in ordinary mode with additional radial correlation channel is applied in this paper to investigate the correlation of the turbulent density fluctuations. The perpendicular correlation length l⊥, the radial correlation length lr and the dissipation (mutation) time τd are measured from the outer core to edge in the L-mode plasmas of ASDEX Upgrade. It is shown that in the outer core region (0.6<ρpol<0.9) the measured correlation lengths scale with the drift wave length, l⊥≈5ρs and lr≈10ρs, while the dissipation time is inversely correlated with the velocity τd≈40/v⊥(τd is in μs and v⊥ in km/s). In the pedestal region (0.925<ρpol<0.98), where the E×B shear flows are present, a loss of measured correlation is observed which can be explained by a combination of small propagation velocity and an additional reduction of τd. In the Er well region (ρpol≈0.99), the perpendicular correlation length increases l⊥≈13ρs and the radial correlation length decreases lr≈4ρs compared to the outer core values. The correlation measurements are interpreted in the frame of the linear regime of reflectometry (applied only to ρpol<0.9). Using the Born approximation we show that the finite wavenumber sensitivity of the reflectometer increases the measured l⊥ and lr, but does not affect the measured τd. By the including diagnostic correction the real correlation lengths l⊥≈lr≈3ρ are estimated.