Clinical usefulness of a collimator distance dependent resolution recovery in myocardial perfusion SPECT: a clinical report from a single institute
- 23 November 2010
- journal article
- Published by Springer Nature in Annals of Nuclear Medicine
- Vol. 25 (2) , 133-137
Abstract
Imperfect image resolution because of finite-sized collimator channels often causes a decrease in diagnostic performance in myocardial perfusion single-photon emission computed tomography (SPECT). This prompted us to evaluate the clinical usefulness of collimator distance dependent resolution recovery (RR) in myocardial perfusion SPECT. We retrospectively reviewed myocardial SPECT images of 60 consecutive patients (26 men, 34 women; mean age 68 years). They consisted of 25 with coronary artery disease (CAD) and 35 without, as confirmed by the coronary angiography (CAG). The patients had undergone myocardial perfusion SPECT imaging with thallium-201 (111 MBq) under an exercise or pharmacological stress protocol. Two readers reviewed the myocardial SPECT images for the presence of CAD on a 4-point scale where 0 = normal, 1 = probably normal, 2 = probably abnormal, and 3 = abnormal. Three reading sessions were held: first, ordered subsets expectation maximization (OSEM) SPECT images, second, OSEM with RR images, and third, both OSEM and RR images. Diagnostic performance for accuracy of coronary arterial stenoses was compared for OSEM, RR and both the images. The sensitivity increased using RR images, but specificity decreased, and thus overall diagnostic accuracy was decreased, as compared with using OSEM images. The overall accuracy of using both the images showed the highest diagnostic performance among the three sets of image interpretations. The sensitivity, specificity and accuracy were 33, 92, 77% for OSEM, 53, 79, 72% for RR and 51, 90, 80% for both the images. These results suggest that RR for myocardial perfusion SPECT imaging has some potential to improve diagnostic accuracy, but both OSEM and RR image sets may have to be employed for the best diagnosis of CAD.Keywords
This publication has 12 references indexed in Scilit:
- A multicenter evaluation of a new post-processing method with depth-dependent collimator resolution applied to full-time and half-time acquisitions without and with simultaneously acquired attenuation correctionJournal of Nuclear Cardiology, 2009
- Initial experience with X-ray ct based attenuation correction in myocardial perfusion spect imaging using a combined spect/ct systemAnnals of Nuclear Medicine, 2005
- Myocardial perfusion SPECT reconstruction: Receiver operating characteristic comparison of CAD detection accuracy of filtered backprojection reconstruction with all of the clinical imaging information available to readers and solely stress slices iteratively reconstructed with combined compensationJournal of Nuclear Cardiology, 2005
- The value and practice of attenuation correction for myocardial perfusion SPECT imaging: A joint position statement from the American Society of Nuclear Cardiology and the Society of Nuclear MedicineJournal of Nuclear Cardiology, 2002
- Improvement of image resolution and quantitative accuracy in clinical Single Photon Emission Computed TomographyComputerized Medical Imaging and Graphics, 2001
- Attenuation corrected cardiac perfusion SPECTCurrent Opinion in Cardiology, 2000
- Combined corrections for attenuation, depth-dependent blur, and motion in cardiac SPECT: A multicenter trialJournal of Nuclear Cardiology, 2000
- Simultaneous Transmission/Emission Myocardial Perfusion TomographyCirculation, 1996
- Quantitative exercise thallium-201 rotational tomography for evaluation of patients with prior myocardial infarctionThe American Journal of Cardiology, 1990
- Quantitative rotational thallium-201 tomography for identifying and localizing coronary artery disease.Circulation, 1988