Single Current Feedback Control Strategy of an LCL Grid-Connected Inverter Based on GI-ESO and Delay Compensation
Open Access
Abstract
This paper presents a new control structure to improve the performance of LCL grid-connected inverters. First, the conventional linear extended state observer (LESO) has difficulty rejecting periodic disturbances, so the proposed method adds an internal model of disturbances into LESO to enhance the harmonic suppression ability. Second, the phase lag caused by the digital delay and LCL resonance make it difficult to ensure the stability of the system. In this paper, the proposed method adds phase compensation for the ESO loop, thus enlarging the stability region of the system with no additional sensors being required. Third, the design of the controller parameters is simplified and the frequency performance analysis of the system is given. Finally, the simulation and experimental results show that the proposed method has good harmonic suppression capability and robust stability.Keywords
Funding Information
- The Hubei Provincial Natural Science Foundation of China (2019CFA040)
- National Natural Science Foundation (NNSF) of China (61703375)
- the 111 Project (B17040)
This publication has 21 references indexed in Scilit:
- Grid-Current-Feedback Active Damping for LCL Resonance in Grid-Connected Voltage-Source ConvertersIEEE Transactions on Power Electronics, 2015
- LCL-Filter Design for Robust Active Damping in Grid-Connected ConvertersIEEE Transactions on Industrial Informatics, 2014
- Capacitor-Current-Feedback Active Damping With Reduced Computation Delay for Improving Robustness of LCL-Type Grid-Connected InverterIEEE Transactions on Power Electronics, 2013
- Regions of Active Damping Control for LCL FiltersIEEE Transactions on Industry Applications, 2013
- Generalized Design of High Performance Shunt Active Power Filter With Output LCL FilterIEEE Transactions on Industrial Electronics, 2011
- Filter-Based Active Damping of Voltage Source Converters With $LCL$ FilterIEEE Transactions on Industrial Electronics, 2010
- A New Feedback Method for PR Current Control of LCL-Filter-Based Grid-Connected InverterIEEE Transactions on Industrial Electronics, 2010
- Limitations of Voltage-Oriented PI Current Control of Grid-Connected PWM Rectifiers With $LCL$ FiltersIEEE Transactions on Industrial Electronics, 2008
- Design and Control of an LCL-Filter-Based Three-Phase Active RectifierIEEE Transactions on Industry Applications, 2005
- Analysis of Multiloop Control Strategies for LC/CL/LCL-Filtered Voltage-Source and Current-Source InvertersIEEE Transactions on Industry Applications, 2005