Effect of Thickness on the Space Charge Behavior and DC Breakdown Strength of Cross-Linked Polyethylene Insulation
Open Access
- 27 April 2020
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 8, 85552-85566
Abstract
In high voltage direct current (HVDC) cable systems, study of electric field distortion created by space charge accumulation is very important for examining insulation performance. Therefore, in this paper the influence of space charge on short-time breakdown characteristics of cross-linked polyethylene (XLPE) are studied. Trap energy distribution is an important factor affecting space charge behavior in dielectrics. Dielectrics with various thicknesses exhibit different space charge phenomena due to various trap distribution characteristics, which regulate the injection, migration and accumulation processes of charges. Consequently, trap characteristics can affect many parameters, such as charge accumulation depth and injection barrier. XLPE with thickness less than 100 μm show lower density of deep traps which can accumulate homogeneous bulk charges as compared to thick XLPE with thickness greater than 100 μm. This phenomenon determines the internal field strength distortion rate which is 20% larger for thin XLPE and it is much higher than that for thick XLPE. The external factor which is considered for analysis is applied field strength and it shows a linear proportional affect on the electric field distortion. A quantitative relationship model between applied field strength and distortion field strength of XLPE with different thicknesses was established. Linear extrapolation was used to obtain the trend of applied, distortion, and actual field strengths at different XLPE thicknesses when breakdown occurred. When the thickness of XLPE is less than 100 μm, distortion field strengths is higher than 50kV/mm and increases with decreasing thickness, resulting in a significant effect on the breakdown phenomenon and breakdown strength increases with increasing thickness. And when the thickness of XLPE is greater than 100 μm, the distortion field strengths is less than 50 kV/mm which also confirms the volume effect on breakdown phenomenon and breakdown strength decreases with increasing thickness.Keywords
Funding Information
- National Basic Research Program of China (2016YFB0900701)
This publication has 31 references indexed in Scilit:
- Electrical tree growth characteristics in XLPE cable insulation under DC voltage conditionsIEEE Transactions on Dielectrics and Electrical Insulation, 2015
- Review of high voltage direct current cablesCSEE Journal of Power and Energy Systems, 2015
- Influence of film thickness on space charge formation under DC ramp voltage2013
- High repetition rate PEA system for in-situ space charge measurement during breakdown testsIEEE Transactions on Dielectrics and Electrical Insulation, 2004
- Space charge distribution measured with short period interval up to electrical breakdown in polyethylene2003
- Acoustic and optical methods for measuring electric charge distributions in dielectrics2003
- Space charge dynamics in LDPE films immediately before breakdownIEEE Transactions on Dielectrics and Electrical Insulation, 2001
- Comparison of AC and DC breakdown behaviour1992
- Electric breakdown strength of aromatic polymers: dependence on film thickness and chemical structureIEEE Transactions on Electrical Insulation, 1991
- Determination of Trapping Parameters from TSC in PolyethyleneJapanese Journal of Applied Physics, 1982