Low Noise Active Shield for SQUID-Based Magnetocardiography Systems
- 18 December 2017
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 28 (4) , 1-5
Abstract
light weight and low-cost active magnetic shield sys-tem is proposed for a single channel SQUID-based magnetocardiog-raphy system equipped for operating at liquid nitrogen temperature without passive magnetic shield. The developed active shield, using coils around the sensors, is a two-stage magnetic shielding system, each stage of which has been designed to compensate different fre-quency and dynamic ranges. The sensor part contains two high-Tc rf-SQUID magnetometers, capable of working stably under earth magnetic field, placed in an axial gradiometric arrangement with a baseline of 10 cm. The active shield setup is driven using two corre-lated proportional-integral-derivative closed loop systems. In the de-signed system, the coils are in the vicinity of the SQUIDs, resulting in coupling the coils to the SQUIDs as well as to the resonators. Hence, the impedance of the coils along with the phase of the feedback current is affected based on the configuration. In this paper, investigation of the shielding performance of our bi-stage mag-netic shield as the active compensation, fed by the optimal feedback control system with all the above considerations, is reported. Using the designed shielding system, the disturbing magnetic signals could be attenuated such that the pico-Tesla signals could be obtained.Keywords
This publication has 19 references indexed in Scilit:
- Magnetocardiogram measured by fundamental mode orthogonal fluxgate arrayJournal of Applied Physics, 2015
- Chamber dimensions and functional assessment with coronary computed tomographic angiography as compared to echocardiography using American Society of Echocardiography guidelinesSage Open Medicine, 2014
- Multi-Channel Magnetocardiogardiography System Based on Low-Tc SQUIDs in an Unshielded EnvironmentPhysics Procedia, 2012
- Development of a Mouse Biomagnetic Measurement System by Using a High-$T_{\rm C}$ SQUID MagnetometerIEEE Transactions on Applied Superconductivity, 2010
- Development of an active magnetic screen to allow a biomagnetometer to be used in an unshielded environmentSuperconductor Science and Technology, 2004
- Active magnetic shielding for biomagnetic measurement using spatial gradient fieldsPhysiological Measurement, 2003
- Dependence of the substrate structure and the film growth at the junction of YBCO SEJ rf-SQUIDs on the IBE process and effects on the SQUID's characteristicsPhysica C: Superconductivity and its Applications, 2002
- A high-Tc dc-SQUID-based single-channel MCG and its per-formanceChinese Science Bulletin, 2002
- Effects of the step structure on the yield, operating temperature, and the noise in step-edge Josephson junction rf-SQUID magnetometers and gradiometersPhysica C: Superconductivity and its Applications, 2001
- Measurements of the magnetocardiography in unshielded environment using high-Tc rf SQUID gradiometerPhysica C: Superconductivity and its Applications, 2000