Accuracy of Barrett versus third-generation intraocular lens formula across all axial lengths
Authors:
Open Access
- 1 September 2022
- journal article
- research article
- Published by Medknow in Oman Journal of Ophthalmology
- Vol. 15 (3) , 290-294
Abstract
PURPOSE: The purpose of this study is to evaluate and compare the accuracy of Barrett Universal II versus third-generation formula for different intraocular lens (IOL) powers for Indian eyes with different axial lengths (ALs). DESIGN: This is a retrospective, nonrandomized consecutive case series. METHODS: This study reviewed 981 eyes from 825 patients who had uneventful cataract surgery and IOL implantation. The eyes were separated into subgroups based on AL as follows: short (24.0 mm). The predicted refractive outcome using formulas was calculated and compared with the actual refractive outcome to give the prediction error. The percentage of every refractive error absolute value for each formula was calculated at <±0.50D, 0.50D-0.75D, and >±0.75D. RESULTS: In all, 981 eyes were analyzed. There were no significant differences in the median absolute error predicted by Barrett and the third-generation formulae. The Barrett Universal II formula resulted in significantly lowest mean spherical equivalent in short eyes (P = 0.0047) as well as a higher percentage of eyes with prediction errors within <±0.50D, 0.50D-0.75D, and >±0.75D. We found that the Barrett Universal II formula had the lowest predictive refraction error and mean absolute error across all ALs. CONCLUSION: The Barrett Universal II formula rendered the lowest predictive error compared with SRK/T, Holladay, and Hoffer Q formulas. Thus, the Barrett Universal II formula may be regarded as a more reliable formula for achieving emmetropia and reducing postoperative refractive surprises across all ALs.Keywords
This publication has 20 references indexed in Scilit:
- Optimising biometry for best outcomes in cataract surgeryEye, 2013
- Comparing optical low coherence reflectometry and immersion ultrasound in refractive outcome after cataract surgeryJournal of Cataract & Refractive Surgery, 2013
- One million cataract surgeries: Swedish National Cataract Register 1992–2009Journal of Cataract & Refractive Surgery, 2011
- Formula choice: Hoffer Q, Holladay 1, or SRK/T and refractive outcomes in 8108 eyes after cataract surgery with biometry by partial coherence interferometryJournal of Cataract & Refractive Surgery, 2011
- Assessment of patient satisfaction with outcomes of and ophthalmic care for cataract surgeryJournal of Cataract & Refractive Surgery, 2010
- Intraocular lens calculation in extreme myopiaJournal of Cataract & Refractive Surgery, 2009
- Biometry and intraocular lens power calculationCurrent Opinion in Ophthalmology, 2008
- Benchmark standards for refractive outcomes after NHS cataract surgeryEye, 2007
- Calculation of intraocular lens power: a reviewActa Ophthalmologica Scandinavica, 2007
- An improved universal theoretical formula for intraocular lens power predictionJournal of Cataract & Refractive Surgery, 1993