Evaluation of structural valve deterioration and bioprosthetic valve failure utilizing the new European consensus definition in patients undergoing TAVI with first-generation devices: Outcomes beyond 5 years from a single center in Turkey
Open Access
- 3 August 2021
- journal article
- research article
- Published by Kare Publishing in The Anatolian Journal of Cardiology
- Vol. 25 (8) , 579-587
Abstract
Objective: The long-term durability of transcatheter aortic bioprosthetic valves continues to be a major concern. Standardized criteria of the structural valve deterioration (SVD) and bioprosthetic valve failure (BVF) have recently been defined. Limited studies have evaluated the longterm durability of transcatheter aortic valve implantation (TAVI) according to these new definitions. We aim to analyze the durability of TAVI beyond 5 years and to report the frequency of SVD and BVF. Methods: A total of 89 patients who had undergone TAVI and had theoretically completed at least 5 years after the procedure were included. Either a Medtronic CoreValve or an Edwards SAPIEN XT valve were implanted in the patients. New standardized definitions were used to evaluate SVD and BVF. Results: The mean age of the patients was 78.70 +/- 6.95 years. SVD occured in 4 (4.5%) patients during 6 years of follow-up. Severe SVD was observed in 2 patients (2.2%), and these patients had the New York Heart Association class II symptoms. Both patients with severe SVD also met the criteria of BVF. Moderate SVD was observed in 2 patients (2.2%), and these patients had no valve-related symptoms. Of the 4 SVD cases, 2 were associated with increased mean transaortic gradients, whereas the remaining 2 cases were associated with intraprosthetic aortic regurgitation. All patients with SVD are still alive, and none of them have required aortic valve reintervention. Conclusion: Although first-generation TAVI devices were used, we determined the low rate of SVD and BVF at the 6-year follow-up. It may be suggested that there is no major concern associated with TAVI even with first-generation devices regarding long-term durability.Keywords
This publication has 41 references indexed in Scilit:
- Transfemoral Aortic Valve Implantation in Patients With an Annulus Dimension Suitable for Either the Edwards Valve or the CoreValveThe American Journal of Cardiology, 2013
- Comparison of Hemodynamic Performance of Self-Expandable CoreValve Versus Balloon-Expandable Edwards SAPIEN Aortic Valves Inserted by Catheter for Aortic StenosisThe American Journal of Cardiology, 2013
- Long-Term Outcomes After Transcatheter Aortic Valve ImplantationJACC, 2012
- Updated standardized endpoint definitions for transcatheter aortic valve implantation: the Valve Academic Research Consortium-2 consensus document†European Heart Journal, 2012
- Guidelines on the management of valvular heart disease (version 2012)European Heart Journal, 2012
- EuroSCORE IIEuropean Journal of Cardio-Thoracic Surgery, 2012
- Doppler haemodynamics and effective orifice areas of Edwards SAPIEN and CoreValve transcatheter aortic valvesEuropean Heart Journal - Cardiovascular Imaging, 2012
- EAE/ASE Recommendations for the Use of Echocardiography in New Transcatheter Interventions for Valvular Heart DiseaseJournal of the American Society of Echocardiography, 2011
- Recommendations for Evaluation of Prosthetic Valves With Echocardiography and Doppler UltrasoundJournal of the American Society of Echocardiography, 2009
- The Society of Thoracic Surgeons 2008 Cardiac Surgery Risk Models: Part 2—Isolated Valve SurgeryThe Annals of Thoracic Surgery, 2009