Experimental studies on sand plug formation in suction caisson during extraction
- 3 October 2017
- journal article
- research article
- Published by Taylor & Francis in Marine Georesources & Geotechnology
- Vol. 36 (7) , 795-804
Abstract
A series of model tests were conducted on Perspex-made suction caissons in saturated dense marine sand to study the sand plug formation during extraction. Suction caissons were extracted by pullout loading or by pumping air into the suction caisson. Effects of the pullout rates, aspect ratios and loading ways (monotonic or sustained) on the pullout capacity, and plug formation were investigated. It was found that the ultimate pullout capacity of the suction caisson increases with increasing the pullout rate. The sand plug formation under the pullout loading is significantly influenced by the pullout rate and the loading way. When the suction caisson is extracted at a relatively slow rate, the general sand boiling through the sand plug along the inner caisson wall occurs. On the contrary, the local sand boiling will occur at the bottom of the suction caisson subjected to a rapid monotonic loading or a sustained loading. Test results of the suction caisson extracted by pumping air into the caisson show that the pressure in the suction caisson almost follows a linear relationship with the upward displacement. The maximum pressures for suction caissons with aspect ratios of 1.0 and 2.0 during extraction by pumping air into the caisson are 1.70 and 2.27 times the maximum suction required to penetrate the suction caisson into sand. It was found that the sand plug moves downward during extraction by pumping air into the caisson and the variation in the sand plug height is mainly caused by the outflow of the sand particles from the inside of the suction caisson to the outside. When the suction caisson model is extracted under the pullout rate of 2 mm/s (0.28 mm/s for the prototype), the hydraulic gradient along the suction caisson wall increases to the maximum value with increasing the penetration depth and then reduces to zero. On the contrary, when extracted under the pullout rate of 10 mm/s (1.4 mm/s for the prototype), the hydraulic gradient along the suction caisson wall increases with increasing the pullout displacement. When extracted by pumping air into the caisson, the hydraulic gradient reaches the critical value, and at the same time, the seepage failure occurs around the suction caisson tip.Keywords
Funding Information
- National Natural Science Foundation of China (51379118,51639002)
- SDUST Research Fund (2015TDJH104)
This publication has 15 references indexed in Scilit:
- Numerical modelling of transient cyclic vertical loading of suction caissons in sandGéotechnique, 2016
- Plastic Flow of Sand and Pullout Capacity of Suction CaissonsJournal of Geotechnical and Geoenvironmental Engineering, 2015
- Model tests of modified suction caissons in marine sand under monotonic lateral combined loadingApplied Ocean Research, 2014
- Extraction of suction caissons in sandGéotechnique, 2014
- Experimental investigation of reverse end bearing of offshore shallow foundationsCanadian Geotechnical Journal, 2013
- An Experimental Investigation of a Shallow Skirted Foundation Under Compression and TensionSoils and Foundations, 2008
- Uplift Capacity of Suction Caissons under Sustained and Cyclic Loading in Soft ClayJournal of Geotechnical and Geoenvironmental Engineering, 2007
- Transient vertical loading of model suction caissons in a pressure chamberGéotechnique, 2006
- Experimental Investigations of the Response of Suction Caissons to Transient Combined LoadingJournal of Geotechnical and Geoenvironmental Engineering, 2004
- Foundations for offshore wind turbinesPhilosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences, 2003