Aortic Cross-Clamping and Reperfusion in Pigs Reduces Microvascular Oxygenation by Altered Systemic and Regional Blood Flow Distribution
Authors:
- Martin SiegemundMSMartin Siegemund
- Jasper van BommelJBJasper van Bommel
- Michiel E. StegengaMSMichiel E. Stegenga
- Wolfgang StuderWSWolfgang Studer
- Mat van ItersonMIMat van Iterson
- Sandra AnnaheimSASandra Annaheim
- Alexandre MebazaaAMAlexandre Mebazaa
- Can InceCICan Ince
- 1 August 2010
- journal article
- Published by Wolters Kluwer Health in Anesthesia & Analgesia
- Vol. 111 (2) , 345-353
Abstract
Ed pigs were randomized between an ACC group (n = 10), undergoing 45 minutes of aortic clamping above the superior mesenteric artery, and a time-matched sham surgery control group (n = 5). Systemic, intestinal, and renal hemodynamics and oxygenation variables were monitored during 4 hours of reperfusion. Microvascular oxygen partial pressure (μPO2) was measured in the intestinal serosa and mucosa and the renal cortex, using the Pd-porphyrin phosphorescence technique. Intestinal luminal PCO2 was determined by air tonometry and the serosal microvascular flow by orthogonal polarization spectral imaging. RESULTS: Organ blood flow and renal and intestinal μPO2 decreased significantly during ACC, whereas the intestinal oxygen extraction and PCO2 gap increased. The intestinal response to reperfusion after ACC was a sustained reactive hyperemia but no such effect was seen in the kidney. Despite a sustained high intestinal O2 delivery, serosal μPO2 (median [range], 49 mm Hg [41–67 mm Hg] versus 37 mm Hg [27–41 mm Hg]; P < 0.05 baseline versus 4 hours reperfusion) and the absolute number of perfused microvessels decreased along with an increased intestinal PCO2 gap (17 mm Hg [10–19 mm Hg] versus 23 mm Hg [19–30 mm Hg]; P < 0.05). In contrast, the kidney showed a progressive O2 delivery decrease accompanied by a decrease in renal cortex oxygenation (70 mm Hg [52–93 mm Hg] versus 57 mm Hg [33–64 mm Hg]; P < 0.05). CONCLUSION: Increased systemic and regional blood flow and oxygen supply after ACC does not ensure adequate regional blood flow and microcirculatory oxygenation in all organs....Keywords
This publication has 29 references indexed in Scilit:
- EFFECTS OF 1400W AND/OR NITROGLYCERIN ON RENAL OXYGENATION AND KIDNEY FUNCTION DURING ENDOTOXAEMIA IN ANAESTHETIZED RATSClinical and Experimental Pharmacology and Physiology, 2009
- l-NIL prevents renal microvascular hypoxia and increase of renal oxygen consumption after ischemia-reperfusion in ratsAmerican Journal of Physiology-Renal Physiology, 2009
- EFFECTS OF INTRARENAL ADMINISTRATION OF THE CALCIUM ANTAGONIST NIMODIPINE DURING PORCINE AORTIC OCCLUSION-INDUCED ISCHEMIA/REPERFUSION INJURYShock, 2008
- Shedding of the Endothelial Glycocalyx in Patients Undergoing Major Vascular Surgery With Global and Regional IschemiaCirculation, 2007
- The endothelial cell in ischemic acute kidney injury: implications for acute and chronic functionKidney International, 2007
- The NO donor SIN‐1 improves intestinal–arterial Pco2 gap in experimental endotoxemia: an animal studyActa Anaesthesiologica Scandinavica, 2007
- Dual-wavelength phosphorimetry for determination of cortical and subcortical microvascular oxygenation in rat kidneyJournal of Applied Physiology, 2006
- Ischaemic preconditioning improves microvascular perfusion and oxygenation following reperfusion injury of the intestineBritish Journal of Surgery, 2005
- Visceral Ischemia and Organ Dysfunction After Thoracoabdominal Aortic Aneurysm RepairAnnals of Surgery, 1996
- The Pathophysiology of Aortic Cross-clamping and UnclampingAnesthesiology, 1995