Simultaneous determination of β2‐agonists in human urine by fast‐gas chromatography/mass spectrometry: method validation and clinical application
- 11 March 2010
- journal article
- research article
- Published by Wiley in Biomedical Chromatography
- Vol. 24 (4) , 358-366
Abstract
A fast screening protocol was developed and validated for the simultaneous determination of 15 β2‐agonists in human urine (bambuterol, cimbuterol, clenbuterol, fenoterol, formoterol, isoproterenol, mapenterol, metaproterenol, procaterol, ractopamine, ritodrine, salbutamol, salmeterol, terbutaline, tulobuterol). The overall sample processing includes deconjugation with enzyme hydrolysis, liquid–liquid extraction, followed by derivatization of the extract and detection of β2‐agonists trimethylsilyl‐derivatives by fast‐gas chromatography/electron impact–mass spectrometry (fast‐GC/EI‐MS). Sample extraction and derivatization were optimized with the purpose of improving recoveries and reaction yields for a variety of analytes with different structures simultaneously, while keeping the procedure simple and reliable. Validation parameters were determined for each analyte under investigation, including selectivity, linearity, intra‐ and inter‐assay precision, extraction recoveries and signal to noise ratio (S/N) at the lowest calibration level. Fast‐GC/MS sequences, based on the use of short columns, high carrier‐gas velocity and fast temperature ramping, allow considerable reduction of the analysis time (7 min), while maintaining adequate chromatographic resolution. The overall GC cycle time was less than 9 min, allowing a processing rate of 6 samples/h. High MS‐sampling rate, using a benchtop quadrupole mass analyzer, resulted in accurate peak shape definition under both scan and selected ion monitoring modes, and high sensitivity in the latter mode. The method was successfully tested on real samples arising from clinical treatments. Copyright © 2009 John Wiley & Sons, Ltd.Keywords
This publication has 21 references indexed in Scilit:
- Application of fast gas chromatography/mass spectrometry for the rapid screening of synthetic anabolic steroids and other drugs in anti‐doping analysisRapid Communications in Mass Spectrometry, 2007
- A general screening method for doping agents in human urine by solid phase extraction and liquid chromatography/time-of-flight mass spectrometryAnalytica Chimica Acta, 2007
- Validated toxicological determination of 30 drugs of abuse as optimized derivatives in oral fluid by long column fast gas chromatography/electron impact mass spectrometryJournal of Mass Spectrometry, 2005
- Three-way models and detection capability of a gas chromatography–mass spectrometry method for the determination of clenbuterol in several biological matrices: the 2002/657/EC European DecisionAnalytica Chimica Acta, 2004
- Liquid chromatography/electrospray ionization tandem mass spectrometric screening and confirmation methods for β2‐agonists in human or equine urineJournal of Mass Spectrometry, 2003
- Diagnostic evidence for the presence of β-agonists using two consecutive derivatization procedures and gas chromatography–mass spectrometric analysisJournal of Chromatography B, 2002
- Fast screening of anabolic steroids and other banned doping substances in human urine by gas chromatography/tandem mass spectrometryJournal of Mass Spectrometry, 2002
- Determination of clenbuterol in human urine by GC–MS–MS–MS: confirmation analysis in antidoping controlJournal of Chromatography B, 2002
- Analytical methodology for the detection of β2-agonists in urine by gas chromatography–mass spectrometry for application in doping controlAnalytica Chimica Acta, 2000
- The SFSTP guide on the validation of chromatographic methods for drug bioanalysis: from the Washington Conference to the laboratoryAnalytica Chimica Acta, 1999