Comparison of the vitality test with sensitivity tests in mature and immature teeth: clinical trial
Open Access
- 27 May 2024
- journal article
- research article
- Published by Springer Nature in BMC Oral Health
- Vol. 24 (1) , 1-7
Abstract
Background: One of the most important steps in deciding on the treatment of a tooth is to determine the vitality and health status of the pulp. Since immature teeth innervation is not completed, the response to sensitivity tests may not yield definite results. Pulse oximetry (PO) which is considered as a vitality test, measures the arterial oxygen saturation (SpO2). This study aims to compare PO, electric pulp test (EPT) and cold test in mature and immature permanent teeth. Methods: 20 immature and 20 mature permanent incisors of 6-12-year-old ASA1 children who did not use any analgesics, were included in the study. Pulp vitality of the teeth was determined by EPT, cold test and PO. An infant probe of PO device (CMS60D, Contec Medical Systems Co. Ltd, China) was used to determine the SpO2 of the teeth. The SpO2 level is controlled on the patient’s finger by a children’s probe and an infant probe of PO. Shapiro-Wilk, Spearman rank correlation test and Kruskal-Wallis test/Dunn post-hoc analysis were used for statistical comparisons. Results: There was no significant correlation between finger SpO2 and the mature/immature teeth SpO2 (r=-0.026, r = 0.253). Arterial oxygen saturation values in the immature teeth were significantly higher than in the mature teeth (p = 0.002). There was a high correlation between the vitality response of the EPT, cold test and PO. Conclusions: Pulse oximetry can be used as an effective vitality test compared to sensitivity tests in both immature and mature permanent incisors.Keywords
This publication has 27 references indexed in Scilit:
- Pulp and Periradicular TestingJournal of Endodontics, 2013
- Comparison of the Efficacy of a Custom-made Pulse Oximeter Probe with Digital Electric Pulp Tester, Cold Spray, and Rubber Cup for Assessing Pulp VitalityJournal of Endodontics, 2012
- Pulse Oximetry: Review of a Potential Aid in Endodontic DiagnosisJournal of Endodontics, 2009
- Comparison of Electrical, Thermal, and Pulse Oximetry Methods for Assessing Pulp Vitality in Recently Traumatized TeethJournal of Endodontics, 2007
- Electric Pulp Tester Conductance Through Various Interface MediaJournal of Endodontics, 2006
- Evaluation of a pulse oximeter and customized probe for pulp vitality testingJournal of Endodontics, 1996
- The hydrodynamic theory of dentinal pain: Sensation in preparations, caries, and the dentinal crack syndromeJournal of Endodontics, 1986
- Assessment of reliability of electrical and thermal pulp testing agentsJournal of Endodontics, 1986
- Evaluation of a digital pulp testerOral Surgery, Oral Medicine, Oral Pathology, 1984
- Quantitative assessment of neural development in human premolarsThe Anatomical Record, 1983