Wavelet‐based index to discriminate between minor inter‐turn short‐circuit and resistive asymmetrical faults in stator windings of doubly fed induction generators: a simulation study
Open Access
- 1 February 2016
- journal article
- research article
- Published by Institution of Engineering and Technology (IET) in IET Generation, Transmission & Distribution
- Vol. 10 (2) , 374-381
Abstract
This study investigates two common types of stator winding faults in doubly fed induction generators (DFIGs) including inter‐turn short‐circuit fault (ITSCF) and winding resistive asymmetrical fault (WRAF), and compares them with the operation of DFIGs underpower grid voltage unbalance conditions. A complete magnetic equivalent circuit model has been used to model ITSCF and WRAF in the stator windings of DFIG. The aim of this investigation is to discriminate between these types of faults using the rotor‐reference‐voltage signals inside the rotor‐side‐converter control system. A new fault diagnostic index (FDI) is proposed based on normalised energy evaluation of the given signal using the discrete wavelet transform. The accuracy of the proposed FDI has been evaluated by simulation of DFIG performances with Matlab/Simulink software under low number of stator shorted turns conditions, different severities of winding resistive asymmetrical faults, various levels of grid voltage unbalance, various rotor speeds, and various output active powers. Analysis of the simulation results confirms that the proposed FDI can accurately discriminate between ITSCF even with minor shorted turns, WRAF or unbalanced voltages except for the cases with minor asymmetry and healthy conditions of stator winding.Keywords
This publication has 34 references indexed in Scilit:
- Analysis of rotor and stator winding inter-turn faults in WRIM using simulated MEC model and experimental resultsElectric Power Systems Research, 2015
- Hybrid modelling of doubly fed induction generators with inter‐turn stator fault and its detection method using wavelet analysisIET Generation, Transmission & Distribution, 2013
- An online technique for condition monitoring the induction generators used in wind and marine turbinesMechanical Systems and Signal Processing, 2013
- Condition monitoring of wind turbine induction generators with rotor electrical asymmetryIET Renewable Power Generation, 2012
- Dynamic model for doubly-fed induction generators with unbalanced excitation, both with and without winding faultsIET Electric Power Applications, 2009
- Analysis of Three-phase Induction Motor Performance under Different Voltage Unbalance Conditions Using Simulation and Experimental ResultsElectric Power Components and Systems, 2009
- Condition Monitoring and ault Diagnosis in Wind Energy Conversion Systems: A Review2007
- Reliability analysis for wind turbinesWind Energy, 2006
- Variable-speed wind power generation using doubly fed wound rotor induction machine-a comparison with alternative schemesIEEE Transactions on Energy Conversion, 2002
- Effects of unbalanced voltage on the operation performance of a three-phase induction motorIEEE Transactions on Energy Conversion, 1999